01 Freelander 2001MY ON Workshop Manual - Service Procedures - 5th Edition - NAS 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 INTRODUCTION26 27 28 29 GENERAL INFORMATION30 31 GENERAL DATA32 IDENTIFICATION NUMBERS33 34 35 TORQUE WRENCH SETTINGS36 37 LIFTING AND TOWING38 CAPACITIES, FLUIDS, LUBRICANTS AND SEALANTS39 MAINTENANCE40 ENGINE - K SERIES KV641 42 43 44 45 46 47 48 EMISSION CONTROL49 50 51 ENGINE MANAGEMENT SYSTEM - SIEMENS52 FUEL DELIVERY SYSTEM - PETROL53 54 COOLING SYSTEM - K SERIES KV655 56 MANIFOLDS & EXHAUST SYSTEMS - K SERIES KV657 58 59 60 INTERMEDIATE REDUCTION DRIVE61 62 63 AUTOMATIC GEARBOX - JATCO64 DRIVESHAFTS65 66 67 REAR AXLE & FINAL DRIVE68 69 70 STEERING71 72 FRONT SUSPENSION73 REAR SUSPENSION74 75 BRAKES76 RESTRAINT SYSTEMS77 78 DOORS79 80 EXTERIOR FITTINGS81 82 INTERIOR TRIM COMPONENTS83 84 85 86 SCREENS87 88 SEATS89 90 91 SUNROOF92 93 HOOD94 95 BODY DIMENSIONS96 97 98 99 PANEL REPAIRS100 101 102 103 104 105 BODY SEALING MATERIALS106 107 108 109 CORROSION PREVENTION AND SEALING110 111 PAINTING112 HEATING AND VENTILATION113 114 AIR CONDITIONING115 116 117 WIPERS AND WASHERS118 CHARGING AND STARTING119 LIGHTING120 121 CONTROL UNITS122 123 SECURITY124 WINDOWS125 IN CAR ENTERTAINMENT126 HARNESSES127 DRIVER CONTROLS128 129 NAVIGATION SYSTEM130 131 INSTRUMENTS
Land Rover Freelander Service Procedures29 · GENERAL INFORMATION
29 · General

GENERAL INFORMATION: Service precautions

Make
Land Rover
Model
Freelander Service Procedures
Section
Service precautions
GENERAL INFORMATIONService precautions
background image

GENERAL INFORMATION

03-30

Remedial actions

If an accident involving R134a should occur, conduct 
the following remedial  actions: 

l

If liquid R134a enters the eye, do not rub it. 
Gently run large quantities of eye wash over 
affected eye to raise the temperature.  If an eye 
wash is not available, cool clean water may be 
used to flush the eye.  After rinsing, cover the 
eye with a clean pad and seek immediate 
medical attention.

l

If liquid R134a is splashed onto the skin, run 
large quantities of water over the affected area 
to raise the temperature. Implement the same 
action if the skin comes in contact with 
discharging cylinders. Wrap the contaminated 
body parts in blankets (or similar materials) and 
seek immediate medical attention.

l

If the debilitating effects of inhalation of R134a 
vapour is suspected,  seek fresh air. If the 
affected person is unconscious, move them 
away from the contaminated area to fresh air 
and apply artificial respiration and/or oxygen 
and seek  immediate medical attention.

Service precautions

Observe the following precautions when handling 
components used in the air conditioning system:

l

Air conditioning units must not be lifted by their 
hoses,  pipes or capillary lines.

l

Hoses and lines must not be subjected to any 
twist or stress - the  efficiency of the system will 
be impaired by kinks or restrictions. Ensure  that 
hoses are correctly positioned before tightening 
couplings, and ensure that all clips and supports 
are utilised.

l

Flexible hoses should not be positioned close to 
the exhaust manifold  (less than 100mm) unless 
protected by heat shielding.

l

Completed assemblies must be checked for 
refrigeration lines touching  metal panels. Any 
direct contact of components and panels may 
transmit noise  and so must be eliminated.

l

The appropriate torque wrench must be used 
when tightening  refrigerant connections to the 
stipulated value. An additional spanner must be  
used to hold the union to prevent twisting of the 
pipe when tightening   connections.

l

Before connecting any hose or pipe, ensure that 
refrigerant oil is  applied to the seat of the new 
'O' ring seals, BUT NOT to the threads of the  
connection.

l

All protective plugs must remain in place to seal 
the component until immediately prior to 
connection.

l

Ensure components are at room temperature 
before uncapping, to prevent   condensation of 
moisture from the air that enters it.  

l

Components must not remain uncapped for 
longer than 15 minutes.  In the event of a delay, 
the caps must be fitted.

l

When disconnecting, immediately cap all air 
conditioning pipes to   prevent ingress of dirt and 
moisture into the system.

l

The modulator (receiver/drier) contains 
desiccant which absorbs moisture. It  must be 
positively sealed at all times. A modulator that 
has been left uncapped must not be used, fit a 
new unit.

l

The modulator should be the last component 
connected to the system to ensure optimum 
dehydration and maximum moisture protection 
of the system.

l

Whenever the refrigerant system is opened, the 
modulator must be renewed immediately before 
evacuating and recharging the system.

l

Use alcohol and a clean lint-free cloth to clean 
dirty connections.

l

Ensure that all new parts fitted are marked for 
use with R134a.

Parts & tools for this job Staging For Land Rover Freelander