Upstream lambda sensor signal error
- Make
- Fiat
- Model
- Doblò Factory Service Manual
- Year
- 2000–2010
- Section
- Examiner › Upstream lambda sensor signal error
UPSTREAM LAMBDA SENSOR SIGNAL ERROR
The diagnostic equipment signals the following error: Upstream Lambda signal
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
Connect the tester (Examiner or Examiner Plus) and transcribe the errors and environmental parameters Check for the 'Upstream Lambda signal' error only | Only the 'Upstream Lambda signal', 'Mixture strength', 'Misfire', 'Catalyzer' and/or 'Downstream Lambda signal' errors are present | Continue to Step 1 | ||
| Other errors present | Identify and eliminate the cause of the anomaly. Continue to Step 8 | |||
| 1 | ERROR DETAIL CHECK | All OK | Problems met | Operation |
Check the detail of the 'Upstream Lambda signal' error In particular, check that it is not 'Open circuit or short circuit to earth' | Continue to Step 3 | The detail is 'Signal not plausible' | See table Z57 UPSTREAM LAMBDA SENSOR SIGNAL ERROR | |
| The detail is 'Open circuit or short circuit to earth' | Continue to Step 2 | |||
| 2 | INTAKE AND EXHAUST SYSTEM LEAKAGE CHECK | All OK | Problems met | Operation |
| Check the exhaust system, See Test 1072A. In particular, check that there are no leaks before the upstream Lambda sensor | Continue to Step 3 | Leaks are present | Eliminate the leaks from the exhaust system, if necessary, replace the components involved | |
| 3 | UPSTREAM LAMBDA SENSOR SWITCHING CHECK | All OK | Problems met | Operation |
Use a tester to cancel the errors in the control unit. Start the engine, let it warm up and check the activation of the 1st loop mixture strength check using the diagnostic equipment (or, alternatively, the switching of the upstream Lambda signal) | Continue to Step 4 | The activation does not take place (or the signal does not switch) | Continue to Step 6 | |
| 4 | LAMBDA SENSOR WIRING CHECK | All OK | Problems met | Operation |
| Check the upstream Lambda sensor wiring, checking that there are no false contacts See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT | Continue to Step 5 | There are false contacts | Restore correct connections. If necessary, replace the defective components Continue to Step 8 | |
| 5 | ECU SOFTWARE CHECK | All OK | Problems met | Operation |
| Using the FIAT documentation, check that the engine management software calibration is updated | Continue to Step 8 | The control unit does not have updated software setting | Reprogramme the engine management control unit. Continue to Step 8 | |
| 6 | LAMBDA SENSOR/ECU INPUT WIRING CHECK | All OK | Problems met | Operation |
| Check the wiring for the upstream Lambda sensor intake circuit in the ECU, checking that there are no short circuits to the supply or to earth, open circuits or false contacts See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT | Continue to Step 7 | There are faulty connections | Restore correct connections. If necessary, replace the defective components Continue to Step 8 | |
| 7 | REPLACING UPSTREAM LAMBDA SENSOR | All OK | Problems met | Operation |
| Replace the upstream Lambda sensor Op. 1080B94 | Continue to Step 8 | |||
| 8 | DELETING AND CHECKING ERROR | All OK | Problems met | Operation |
Use a tester to cancel the errors in the control unit. Carry out a road test and ensure the error does not recur | Continue to Step 9 | The fault persists, it is the first time that this step has been reached and the Lambda sensor has not yet been replaced | Continue to Step 0 | |
| The fault persists, but it is the second time that this step has been reached, or the Lambda sensor has already been replaced | Contact Technical Support for further information on the problem | |||
| 9 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | ||
The diagnostic equipment signals the following error: Upstream Lambda signal
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
Connect the tester (Examiner or Examiner Plus) and transcribe the errors and environmental parameters Check for the 'Upstream Lambda signal' error only | End of diagnosis | Only the 'Upstream Lambda signal', 'Mixture strength', 'Misfire', 'Catalyzer' and/or 'Downstream Lambda signal' errors are present | Continue to Step 1 | |
| Other errors present | Identify and eliminate the cause of the anomaly. Continue to Step 8 | |||
| 1 | ERROR DETAIL CHECK | All OK | Problems met | Operation |
Check the detail of the 'Upstream Lambda signal' error In particular, check that it is not 'Open circuit or short circuit to earth' | Continue to Step 3 | The detail is 'Signal not plausible' | Continue according to the instructions for the See table Z57 UPSTREAM LAMBDA SENSOR SIGNAL ERROR | |
| The detail is 'Open circuit or short circuit to earth' | Continue to Step 2 | |||
| 2 | INTAKE AND EXHAUST SYSTEM LEAKAGE CHECK | All OK | Problems met | Operation |
| Check the exhaust system visually and by listening. In particular, check that there are no leaks before the upstream Lambda sensor | Continue to Step 3 | Leaks are present | Eliminate the leaks from the exhaust system, if necessary, replace the components involved | |
| 3 | UPSTREAM LAMBDA SENSOR SWITCHING CHECK | All OK | Problems met | Operation |
Use a tester to cancel the errors in the control unit. Start the engine, let it warm up and check the activation of the 1st loop mixture strength check using the diagnostic equipment (or, alternatively, the switching of the upstream Lambda signal) | Continue to Step 4 | The activation does not take place (or the signal does not switch) | Continue to Step 6 | |
| 4 | LAMBDA SENSOR WIRING CHECK | All OK | Problems met | Operation |
| Check the upstream Lambda sensor wiring, checking that there are no false contacts See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT | Continue to Step 5 | There are false contacts | Restore correct connections. If necessary, replace the defective components Continue to Step 8 | |
| 5 | ECU SOFTWARE CHECK | All OK | Problems met | Operation |
| Using the FIAT documentation, check that the engine management software calibration is updated | Continue to Step 8 | The control unit does not have updated software setting | Reprogramme the engine management control unit. Continue to Step 8 | |
| 6 | LAMBDA SENSOR/ECU INPUT WIRING CHECK | All OK | Problems met | Operation |
| Check the wiring for the upstream Lambda sensor intake circuit in the ECU, checking that there are no short circuits to the supply or to earth, open circuits or false contacts See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT | Continue to Step 7 | There are faulty connections | Restore correct connections. If necessary, replace the defective components Continue to Step 8 | |
| 7 | REPLACING UPSTREAM LAMBDA SENSOR | All OK | Problems met | Operation |
| Replace the upstream Lambda sensor Op. 1080B60 | Continue to Step 8 | |||
| 8 | DELETING AND CHECKING ERROR | All OK | Problems met | Operation |
Use a tester to cancel the errors in the control unit. Carry out a road test and ensure the error does not recur | Continue to Step 9 | The fault persists, it is the first time that this step has been reached and the Lambda sensor has not yet been replaced | Continue to Step 0 | |
| The fault persists, but it is the second time that this step has been reached, or the Lambda sensor has already been replaced | Contact Technical Support for further information on the problem | |||
| 9 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | ||
The diagnostic equipment signals the following error: Upstream Lambda signal (slow)
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
Connect the tester (Examiner or Examiner Plus) and transcribe the errors and environmental parameters Check for the 'Upstream Lambda signal (slow)' error only | 'Upstream lambda probe' error present | See table Z56 UPSTREAM LAMBDA SENSOR SIGNAL ERROR | ||
| Only the 'Upstream Lambda signal (slow)', 'Mixture strength', 'Misfire', 'Catalyzer' and/or 'Downstream Lambda signal' errors are present | Continue to Step 1 | |||
| Other errors present | Identify and eliminate the cause of the anomaly. Continue to Step 4 | |||
| 1 | SENSOR CHECK | All OK | Problems met | Operation |
Visually inspect:
| Continue to Step 2 | Lambda sensor fitted incorrectly | Fit the Lambda sensor correctly Op. 1080B94 Continue to Step 4 | |
| Terminals corroded | Replace faulty components Continue to Step 4 | |||
| Wiring faulty | Restore correct connections. If necessary, replace the faulty components See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT Continue to Step 4 | |||
| 2 | EXHAUST SYSTEM CHECK | All OK | Problems met | Operation |
| Check the exhaust system, See Test 1072A. In particular, check that there are no leaks from the head outlet to the downstream Lambda sensor | Continue to Step 3 | Leaks are present | Restore the exhaust system seal and replace the affected parts if necessary Continue to Step 4 | |
| 3 | REPLACING UPSTREAM LAMBDA SENSOR | All OK | Problems met | Operation |
Replace the upstream Lambda sensor Op. 1080B94 Search for the cause of the pollution in the sensor. The probable causes are:
| Continue to Step 4 | Use of contaminated petrol | Clean the tank Op. 1040A10and introduce suitable quality fuel. Continue to Step 4 | |
| Engine oil leaks detected | See table X12 ENGINE OIL LEAKS | |||
| 4 | DELETING AND CHECKING ERROR | All OK | Problems met | Operation |
Use a tester to cancel the errors in the control unit. Carry out a road test and ensure the error does not recur | Continue to Step 5 | The fault persists, it is the first time that this step has been reached and the Lambda sensor has not yet been replaced | Continue to Step 0 | |
| The fault persists, but it is the second time that this step has been reached or the Lambda sensor has already been replaced | Contact Technical Support for further information on the problem | |||
| 5 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | ||
The diagnostic equipment signals the following error: Upstream Lambda signal (slow)
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
Connect the tester (Examiner or Examiner Plus) and transcribe the errors and environmental parameters Check for the 'Upstream Lambda signal (slow)' error only | End of diagnosis | 'Upstream lambda probe' error present | Continue according to the instructions for the See table Z56 UPSTREAM LAMBDA SENSOR SIGNAL ERROR | |
| Only the 'Upstream Lambda signal (slow)', 'Mixture strength', 'Misfire', 'Catalyzer' and/or 'Downstream Lambda signal' errors are present | Continue to Step 1 | |||
| Other errors present | Identify and eliminate the cause of the anomaly. Continue to Step 3 | |||
| 1 | SENSOR CHECK | All OK | Problems met | Operation |
Visually inspect:
| Continue to Step 2 | Lambda sensor fitted incorrectly | Fit the Lambda sensor correctly Op. 1080B94 Continue to Step 3 | |
| Terminals corroded | Replace faulty components Continue to Step 3 | |||
| Wiring faulty | Restore correct connections. If necessary, replace the faulty components See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT Continue to Step 3 | |||
| 2 | REPLACING UPSTREAM LAMBDA SENSOR | All OK | Problems met | Operation |
Replace the upstream Lambda sensor Op. 1080B94 Search for the cause of the pollution in the sensor. The probable causes are:
| Continue to Step 3 | Use of contaminated petrol | Clean the tank Op. 0010T22and introduce suitable quality fuel. Continue to Step 3 | |
| Engine oil leaks detected | Continue according to the instructions for the See table X12 ENGINE OIL LEAKS | |||
| 3 | DELETING AND CHECKING ERROR | All OK | Problems met | Operation |
Use a tester to cancel the errors in the control unit. Carry out a road test and ensure the error does not recur | Continue to Step 4 | The fault persists, it is the first time that this step has been reached and the Lambda sensor has not yet been replaced | Continue to Step 0 | |
| The fault persists, but it is the second time that this step has been reached or the Lambda sensor has already been replaced | Contact Technical Support for further information on the problem | |||
| 4 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | ||
Parts & tools for this job Staging For 2000 Fiat Doblò
- PARTOxygen sensorSearch: Fiat Doblò 2000 oxygen sensor
- TOOLOxygen sensor socketSearch: oxygen sensor socket
- TOOLOBD2 scannerSearch: OBD2 scanner
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.