Workshop Manuals Factory service & repair Fiat
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Doblò Factory Service Manual (2000-2010)22 · Fault diagnosis
22 · Diagnostics

Downstream lambda sensor signal error

Make
Fiat
Model
Doblò Factory Service Manual
Year
2000–2010
Section
Examiner › Downstream lambda sensor signal error
Fault diagnosisDownstream lambda sensor signal error

DOWNSTREAM LAMBDA SENSOR SIGNAL ERROR

The diagnostic equipment signals the following error: Downstream Lambda signal

Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation

Connect the tester (Examiner or Examiner Plus) and transcribe the errors and environmental parameters

Check for the 'Downstream Lambda signal' error only

'Upstream lambda probe' error presentSee table Z56 UPSTREAM LAMBDA SENSOR SIGNAL ERROR
'Mixture concentration' error presentSee table Z50 MIXTURE STRENGTH ERROR
The 'Misfire' error is presentSee table Z53 MISFIRE ERROR
The 'Downstream Lambda signal' and/or 'Catalyzer ' errors are presentContinue to Step 1
Other errors present

Identify and eliminate the cause of the anomaly.

Continue to Step 8

1ERROR DETAIL CHECKAll OKProblems metOperation

Check the detail of the 'Downstream Lambda signal' error

In particular, check that it is not 'Open circuit or short circuit to earth'

Continue to Step 3The detail is 'Open circuit or short circuit to earth'Continue to Step 2
2INTAKE AND EXHAUST SYSTEM LEAKAGE CHECKAll OKProblems metOperation
Check the exhaust system, See Test 1072AIn particular, check that there are no leaks from the head outlet to the downstream Lambda sensorContinue to Step 3Leaks are presentEliminate the leaks from the exhaust system, if necessary, replace the components involved
3DOWNSTREAM LAMBDA SENSOR SWITCHING CHECKAll OKProblems metOperation

Use a tester to cancel the errors in the control unit.

Road test the vehicle and check the activation of the 2nd closed loop using the diagnostic equipment

Continue to Step 4The activation does not take place (or the signal does not switch)Continue to Step 6
4LAMBDA SENSOR WIRING CHECKAll OKProblems metOperation
Check the downstream Lambda sensor wiring, checking that there are no false contacts See E5030 PETROL ENGINE ELECTRONIC MANAGEMENTContinue to Step 5There are false contacts

Restore correct connections. If necessary, replace the defective components

Continue to Step 8

5ECU SOFTWARE CHECKAll OKProblems metOperation
Check that the engine management control unit software calibration is updatedContinue to Step 8The control unit calibration is not updated

Reprogramme the engine management control unit.

Continue to Step 8

6LAMBDA SENSOR/ECU INPUT WIRING CHECKAll OKProblems metOperation
Check the wiring for the downstream Lambda sensor input wiring in the ECU, checking that there are no short circuits to the supply or earth, open circuits or false contacts See E5030 PETROL ENGINE ELECTRONIC MANAGEMENTContinue to Step 7There are faulty connections

Restore correct connections. If necessary, replace the defective components

Continue to Step 8

7REPLACING DOWNSTREAM LAMBDA SENSORAll OKProblems metOperation
Replace the downstream Lambda sensor Op. 1080B95Continue to Step 8
8DELETING AND CHECKING ERRORAll OKProblems metOperation

Use a tester to cancel the errors in the control unit.

Carry out a road test and ensure the error does not recur

Continue to Step 9The fault persists, it is the first time that this step has been reached and the Lambda sensor has not yet been replacedContinue to Step 0
The fault persists, but it is the second time that this step has been reached, or the Lambda sensor has already been replacedContact Technical Support for further information on the problem
9CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persists

The diagnostic equipment signals the following error: Downstream Lambda signal

Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation

Connect the tester (Examiner or Examiner Plus) and transcribe the errors and environmental parameters

Check for the 'Downstream Lambda signal' error only

End of diagnosis'Upstream lambda probe' error presentContinue according to the instructions for the See table Z56 UPSTREAM LAMBDA SENSOR SIGNAL ERROR
'Mixture concentration' error presentContinue according to the instructions for the See table Z50 MIXTURE STRENGTH ERROR
The 'Misfire' error is presentContinue according to the instructions for the See table Z53 MISFIRE ERROR
The 'Downstream Lambda signal' and/or 'Catalyzer ' errors are presentContinue to Step 1
Other errors present

Identify and eliminate the cause of the anomaly.

Continue to Step 8

1ERROR DETAIL CHECKAll OKProblems metOperation

Check the detail of the 'Downstream Lambda signal' error

In particular, check that it is not 'Open circuit or short circuit to earth'

Continue to Step 3The detail is 'Open circuit or short circuit to earth'Continue to Step 2
2INTAKE AND EXHAUST SYSTEM LEAKAGE CHECKAll OKProblems metOperation
Check the exhaust system visually and by listening In particular, check that there are no leaks from the head outlet to the downstream Lambda sensorContinue to Step 3Leaks are presentEliminate the leaks from the exhaust system, if necessary, replace the components involved
3DOWNSTREAM LAMBDA SENSOR SWITCHING CHECKAll OKProblems metOperation

Use a tester to cancel the errors in the control unit.

Road test the vehicle and check the activation of the 2nd closed loop using the diagnostic equipment

Continue to Step 4The activation does not take place (or the signal does not switch)Continue to Step 6
4LAMBDA SENSOR WIRING CHECKAll OKProblems metOperation
Check the downstream Lambda sensor wiring, checking that there are no false contacts See E5030 PETROL ENGINE ELECTRONIC MANAGEMENTContinue to Step 5There are false contacts

Restore correct connections. If necessary, replace the defective components

Continue to Step 8

5ECU SOFTWARE CHECKAll OKProblems metOperation
Check that the engine management control unit software calibration is updatedContinue to Step 8The control unit calibration is not updated

Reprogramme the engine management control unit.

Continue to Step 8

6LAMBDA SENSOR/ECU INPUT WIRING CHECKAll OKProblems metOperation
Check the wiring for the downstream Lambda sensor input wiring in the ECU, checking that there are no short circuits to the supply or earth, open circuits or false contacts See E5030 PETROL ENGINE ELECTRONIC MANAGEMENTContinue to Step 7There are faulty connections

Restore correct connections. If necessary, replace the defective components

Continue to Step 8

7REPLACING DOWNSTREAM LAMBDA SENSORAll OKProblems metOperation
Replace the downstream Lambda sensor Op. 1080B60Continue to Step 8
8DELETING AND CHECKING ERRORAll OKProblems metOperation

Use a tester to cancel the errors in the control unit.

Carry out a road test and ensure the error does not recur

Continue to Step 9The fault persists, it is the first time that this step has been reached and the Lambda sensor has not yet been replacedContinue to Step 0
The fault persists, but it is the second time that this step has been reached, or the Lambda sensor has already been replacedContact Technical Support for further information on the problem
9CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persists

Parts & tools for this job Staging For 2000 Fiat Doblò

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.