Catalyzer error
- Make
- Fiat
- Model
- Doblò Factory Service Manual
- Year
- 2000–2010
- Section
- Examiner › Catalyzer error
CATALYZER ERROR
The diagnostic equipment signals the following error: Catalyzer
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
Connect the tester (Examiner or Examiner Plus) and transcribe the errors and environmental parameters Check for the 'Catalyzer' error only | 'Upstream lambda probe' error present | See table Z56 UPSTREAM LAMBDA SENSOR SIGNAL ERROR | ||
| 'Mixture concentration' error present | See table Z50 MIXTURE STRENGTH ERROR | |||
| The 'Misfire' error is present | See table Z53 MISFIRE ERROR | |||
| The 'Downstream Lambda signal' error is present | See table Z58 DOWNSTREAM LAMBDA SENSOR SIGNAL ERROR | |||
| The 'Catalyzer' error only is present | Continue to Step 1 | |||
| Other errors present | Identify and eliminate the cause of the anomaly. Continue to Step 5 | |||
| 1 | EXHAUST SYSTEM LEAKS CHECK | All OK | Problems met | Operation |
Look and listen to check the exhaust system from the cylinder head outlet to the downstream lambda probe. Check that there are no leaks | Continue to Step 2 | There are leaks | Restore the exhaust system seal and replace the affected parts if necessary Continue to Step 5 | |
| 2 | ROAD TEST TO CHECK MIXTURE STRENGTH | All OK | Problems met | Operation |
| Road test the vehicle and check the mixture strength in the 1st and 2nd closed loops using the diagnostic equipment. Check that the activation is correct | Continue to Step 3 | The 1st closed loop activation is not correct | See table Z56 UPSTREAM LAMBDA SENSOR SIGNAL ERROR | |
| The 2nd closed loop activation is not correct | See table Z58 DOWNSTREAM LAMBDA SENSOR SIGNAL ERROR | |||
| 3 | CHECKING INLET AND EXHAUST SYSTEM SEAL | All OK | Problems met | Operation |
Check the exhaust system and ensure there are no leaks from the cylinder head outlet to the upstream lambda probe See Test 1072Ato check seal of the inlet and exhaust system | Continue to Step 4 | Seal not correct | Restore system seal and replace the affected parts if necessary Continue to Step 5 | |
| 4 | REPLACING THE CATALYZER | All OK | Problems met | Operation |
| Replace the catalyzer Op. 1076C16 | Continue to Step 5 | |||
| 5 | DELETING AND CHECKING ERROR | All OK | Problems met | Operation |
Use a tester to cancel the errors in the control unit. Carry out a road test and ensure the error does not recur | Continue to Step 6 | The fault persists, it is the first time that this step has been reached and the catalyzer has not yet been replaced | Continue to Step 0 | |
| The fault persists, but it is the second time that this step has been reached or the catalyzer has already been replaced | Contact Technical Support for further information on the problem | |||
| 6 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | ||
The diagnostic equipment signals the following error: Catalyzer
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
Connect the tester (Examiner or Examiner Plus) and transcribe the errors and environmental parameters Check for the 'Catalyzer' error only | End of diagnosis | 'Upstream lambda probe' error present | Continue according to the instructions for the See table Z56 UPSTREAM LAMBDA SENSOR SIGNAL ERROR | |
| 'Mixture concentration' error present | Continue according to the instructions for the See table Z50 MIXTURE STRENGTH ERROR | |||
| The 'Misfire' error is present | Continue according to the instructions for the See table Z53 MISFIRE ERROR | |||
| The 'Downstream Lambda signal' error is present | Continue according to the instructions for the See table Z58 DOWNSTREAM LAMBDA SENSOR SIGNAL ERROR | |||
| The 'Catalyzer' error only is present | Continue to Step 1 | |||
| Other errors present | Identify and eliminate the cause of the anomaly. Continue to Step 5 | |||
| 1 | EXHAUST SYSTEM LEAKS CHECK | All OK | Problems met | Operation |
Look and listen to check the exhaust system from the cylinder head outlet to the downstream lambda probe. Check that there are no leaks | Continue to Step 2 | There are leaks | Restore the exhaust system seal and replace the affected parts if necessary Continue to Step 5 | |
| 2 | ROAD TEST TO CHECK MIXTURE STRENGTH | All OK | Problems met | Operation |
| Road test the vehicle and check the mixture strength in the 1st and 2nd closed loops using the diagnostic equipment. Check that the activation is correct | Continue to Step 3 | The 1st closed loop activation is not correct | Continue according to the instructions for the See table Z56 UPSTREAM LAMBDA SENSOR SIGNAL ERROR | |
| The 2nd closed loop activation is not correct | Continue according to the instructions for the See table Z58 DOWNSTREAM LAMBDA SENSOR SIGNAL ERROR | |||
| 3 | CHECKING INLET AND EXHAUST SYSTEM SEAL | All OK | Problems met | Operation |
| Check the exhaust system visually and by listening, to check that there are no leaks from the cylinder head outlet to the upstream lambda sensor | Continue to Step 4 | Seal not correct | Restore system seal and replace the affected parts if necessary Continue to Step 5 | |
| 4 | REPLACING THE CATALYZER | All OK | Problems met | Operation |
| Replace the catalyzer Op. 1080B62 | Continue to Step 5 | |||
| 5 | DELETING AND CHECKING ERROR | All OK | Problems met | Operation |
Use a tester to cancel the errors in the control unit. Carry out a road test and ensure the error does not recur | Continue to Step 6 | The fault persists, it is the first time that this step has been reached and the catalyzer has not yet been replaced | Continue to Step 0 | |
| The fault persists, but it is the second time that this step has been reached or the catalyzer has already been replaced | Contact Technical Support for further information on the problem | |||
| 6 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | ||
Parts & tools for this job Staging For 2000 Fiat Doblò
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLSocket setSearch: socket set metric
- BOOKHaynes manualSearch: Haynes manual Fiat Doblò
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.