01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Multipla Factory Service Manual (1998-2010)08 · Engine
08 · Engine

Introduction - ENGINE COOLING

Make
Fiat
Model
Multipla Factory Service Manual
Year
1998–2010
Section
Engine cooling › Introduction - ENGINE COOLING
EngineIntroduction - ENGINE COOLING

Introduction - ENGINE COOLING

1.6 16v

Introduction - ENGINE COOLING

1, Water pump

2, Engine coolant temperature sensor (see DESCRIPTION AND OPERATION: 1056 PETROL INJECTION SYSTEM)

3, Thermostat

4, Radiator

5, Electric fan

6, Reservoir

7, Water pump rigid inlet pipe

8, Heater unit

In addition to supplying the system, the reservoir also absorbs the variations in volume of the cooling liquid, as the engine temperature varies.

Through a specific calibrated valve, contained in the pressurized cap:

  • air emerges from the collection circuit from the pipe coming from the thermostat
  • air enters when the circuit is in a vacuum (because of the engine cooling).

For leak test and test on pressurized cap 0510C30 cooling system - tightness test.

RADIATOR

This consists of a radiating mass and two side chambers acting as the coolant to inlet and outlet.

The tubes and fins of the radiating mass are of aluminium, and the reservoirs are of plastic.

WATER PUMP

It is the centrifugal type with vanes, fixed to the crankcase and directly directly by the timing belt.

THERMOSTAT

Mounted on the rear of the cylinder head, its function is to keep the engine at the optimum temperature:

  • at a temperature of < 83 ± 2°C, the (closed) thermostatic valve directs the coolant directly to the pump
  • at a temperature of > 83 ± 2°C, the (open) thermostatic valve directs the coolant to the radiator.

Mounted on the thermostat, there is the coolant temperature sensor connected to the fuel injection control unit (see DESCRIPTION AND OPERATION: 1056 PETROL INJECTION SYSTEM).

ELECTRIC FAN

The two speed electric cooling fan makes it possible to increase the dissipation of the heat from the radiator and/or the air conditioning system condenser.

It is controlled directly by the injection control unit in accordance with a specific operating logic ( see DESCRIPTION AND OPERATION: 1056 PETROL INJECTION SYSTEM).

1.9 JTD 8V

Introduction - ENGINE COOLING

1, Water pump

2, Heater unit

3, Engine coolant temperature sensor (see 1060)

4, Thermostat

5, Radiator

6, Electric fans

7, Supply reservoir

8, Rigid water inlet pipe to pump

9, Water-oil exchanger

RESERVOIR

In addition to supplying the system, the reservoir also absorbs the variations in volume of the cooling liquid, as the engine temperature varies.

Through a specific calibrated valve, contained in the pressurized cap:

  • air emerges from the collection circuit from the pipe coming from the thermostat
  • air enters when the circuit is in a vacuum (because of the engine cooling).

RADIATOR (VERSION WITH HEATER)

This consists of a radiating mass and two side chambers acting as the coolant to inlet and outlet.

The coolant inlet and outlet pipes are connected to the left reservoir, in order to convey the fluid along a C-shaped route in the radiating mass.

The tubes and fins of the radiating mass are of aluminium, and the reservoirs are of plastic.

Introduction - ENGINE COOLING

RADIATOR (VERSION WITH AIR CONDITIONING)

This consists of a radiating mass and two side chambers, one top and one bottom, for circulation of the coolant. The coolant inlet and outlet pipes are connected to the top reservoir, in order to convey the fluid along a U-shaped route in the radiating mass.

The tubes and fins of the radiating mass and the reservoirs are of metal.

Introduction - ENGINE COOLING

WATER PUMP

It is the centrifugal vane type, with an aluminium alloy pump casing and phenolic resin impeller.

Secured to the engine block and driven directly by the timing belt.

Introduction - ENGINE COOLING

THERMOSTAT

Mounted on the rear of the cylinder head, its function is to keep the engine at the optimum temperature:

  • at a temperature of < 80 ± 2°C the (closed) thermostatic valve directs the coolant directly to the pump
  • at a temperature of > 80 ± 2°C the (open) thermostatic valve directs the coolant to the radiator.

Mounted on the thermostat, there is the coolant temperature sensor connected to the fuel injection control unit (see 1060).

1.6 16v · BIPOWER, Euro 3

CONSTRUCTION FEATURES

The engine cooling circuit consists of:

  • Water pump (1)
  • Engine coolant temperature sensor (2) ()
  • Thermostat (3)
  • Radiator (4)
  • Radiator cooling fan (5)
  • Reservoir (6)
  • Rigid pump water inlet pipe (7)
  • Heater unit (8)
  • Methane pressure reduction unit (9)
Introduction - ENGINE COOLING

Parts & tools for this job Staging For 1998 Fiat Multipla

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.