Rich fuel system
- Make
- Fiat
- Model
- Doblò Factory Service Manual
- Year
- 2000–2010
- Section
- Examiner › Rich fuel system
RICH FUEL SYSTEM
| Results of the tests | ||||
| 1 | CANISTER VALVE CHECK | All OK | Problems met | Operation |
|---|---|---|---|---|
| Check that the canister valve is not stuck open | Continue to Step 2 | Canister valve stuck open | Repair or, if necessary, replace the canister Op. 1080E20 Continue to Step 6 | |
| 2 | INTAKE AND EXHAUST SYSTEM LEAKAGE CHECK | All OK | Problems met | Operation |
Check the blow-by circuit See Test 1072A In particular, check that there are no leaks from the engine sump to the intake circuit | Continue to Step 3 | Leaks are present | Eliminate leaks from the system. Replace faulty parts if necessary Continue to Step 6 | |
| 3 | PETROL PRESSURE CHECK | All OK | Problems met | Operation |
Turn the key to MAR and check fuel pump activates. Whilst the pump is activated, check that the fuel pressure is not too high | Continue to Step 4 | High pressure: fuel pressure regulator setting not correct | Calibrate correctly. Continue to Step 6 | |
| High pressure: fuel pressure regulator faulty | Replace the fuel pump Op. 1040A70 Continue to Step 6 | |||
| 4 | CHECK ON FUEL INJECTORS | All OK | Problems met | Operation |
Check the mechanical seal of the injectors. In particular, check that none of the injectors are stuck open | Continue to Step 5 | Injectors defective | Renew the correct seal for the injectors, if necessary replace them Op. 1056B70 Continue to Step 6 | |
| 5 | UPSTREAM LAMBDA SENSOR CHECK | All OK | Problems met | Operation |
| Starting from Step 3 See table Z56 UPSTREAM LAMBDA SENSOR SIGNAL ERROR | End of diagnosis | |||
| 6 | DELETING AND CHECKING ERROR | All OK | Problems met | Operation |
Use a tester to cancel the errors in the control unit. Carry out a road test and ensure the error does not recur | Continue to Step 7 | The fault persists | See table Z50 MIXTURE STRENGTH ERROR | |
| 7 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | ||
| Results of the tests | ||||
| 1 | CANISTER VALVE CHECK | All OK | Problems met | Operation |
|---|---|---|---|---|
| Check that the canister valve is not stuck open | Continue to Step 2 | Canister valve stuck open | Repair or, if necessary, replace the canister Op. 1080E20 Continue to Step 5 | |
| 2 | INTAKE AND EXHAUST SYSTEM SEAL CHECK | All OK | Problems met | Operation |
Check the blow-by circuit, visually checking that there are no leaks from the engine sump to the intake circuit. Also check, visually and by listening, that there are no leaks from the intake and exhaust systems | Continue to Step 3 | Leaks are present | Eliminate leaks from the system. Replace faulty parts if necessary Continue to Step 5 | |
| 3 | PETROL PRESSURE CHECK | All OK | Problems met | Operation |
Turn the key to MAR and check fuel pump activates. While the pump is active, check fuel pressure is not too high. Turn the ignition off and check that the pressure does not fall by a more than 1 bar over a period of 15 minutes. | Continue to Step 4 | High pressure: fuel pressure regulator setting not correct | Replace the fuel pump Op. 1040A70 Continue to Step 5 | |
| The pressure falls by more than 1 bar in the established time: faulty injectors | Renew the correct seal for the injectors, if necessary replace them Op. 1056B70 Continue to Step 5 | |||
| The pressure falls by more than 1 bar in the established time: leaks from the fuel pressure regulator | Replace the fuel pump Op. 1040A70 Continue to Step 5 | |||
| The pressure falls by more than 1 bar in the established time: leaks from the non-return valve on the fuel pump | Replace the fuel pump Op. 1040A70 Continue to Step 5 | |||
| 4 | UPSTREAM LAMBDA SENSOR CHECK | All OK | Problems met | Operation |
| Continue according to the instructions for the See table Z56 UPSTREAM LAMBDA SENSOR SIGNAL ERROR | Continue to Step 3 | |||
| 5 | DELETING AND CHECKING ERROR | All OK | Problems met | Operation |
Use a tester to cancel the errors in the control unit. Carry out a road test and ensure the error does not recur | Continue to Step 6 | The fault persists | Continue to Step 1 | |
| 6 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | The fault persists | ||
Parts & tools for this job Staging For 2000 Fiat Doblò
- PARTFuel filterSearch: Fiat Doblò 2000 fuel filter
- TOOLFuel pressure test kitSearch: fuel pressure test kit
- TOOLFuel line disconnect toolSearch: fuel line disconnect tool
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.