HIGH CO EMISSIONS
The percentage of CO and/or HC is higher than the recommended figure.
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
| Check the condition of the air filter | Continue to Step 1 | Filter element dirty or damaged | Replace the filter element | |
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socket Check that there are no fault in the engine management control unit | Continue to Step 2 | 'Supply system' error detected | See table Z50 | |
| 'Misfire' error detected | See table Z53 | |||
| 'Catalytic converter' error detected | See table Z55 | |||
| 'Upstream lambda sensor' error detected | See table Z56 | |||
| 'Downstream lambda sensor' error detected | See table Z58 | |||
| Another error dected in the control unit | Continue following the instructions for the diagnostic equipment. | |||
| Lack of dialogue with the control unit | Restore the connection between the engine management control unit and the diagnostic connector See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT | |||
| 2 | ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
Using the diagnostic equipment (Examiner or other iinstruments) carry out active diagnosis on the:
| Continue to Step 3 | Connections faulty | Restore the connection of the injectors and the solenoid with the control unit See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT | |
| Solenoid valve faulty | Replace the solenoid valve Op. 1080E28 | |||
| Injector faulty | Replace injector Op. 1056B70 | |||
| 3 | UPSTREAM LAMBDA SENSOR CHECK | All OK | Problems met | Operation |
| Check that the upstream Lambda sensor is working properly. | Continue to Step 4 | Lambda sensor faulty | Replace the Lambda sensor Op. 1080B94 | |
| 4 | DOWNSTREAM LAMDBA SENSOR CHECK | All OK | Problems met | Operation |
| Check that the downstream Lambda sensor is working properly. | Continue to Step 5 | Lambda sensor faulty | Replace the Lambda sensor Op. 1080B95 | |
| 5 | CHECKING AIR CIRCUIT | All OK | Problems met | Operation |
| Check the condition of the air supply circuit | Continue to Step 6 | Circuit component damaged | Replace the component involved | |
| 6 | CHECK ON FUEL PRESSURE | All OK | Problems met | Operation |
| Check the fuel supply pressure Op. 0510C10 | Continue to Step 7 | Pressure not correct | Replace the fuel pupm | |
| 7 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | ||
The percentage of CO and/or HC is higher than the recommended figure.
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
| Check the condition of the air filter | Continue to Step 1 | Filter element dirty or damaged | Replace the filter element | |
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socket Check that there are no fault in the engine management control unit | Continue to Step 2 | 'Supply system' error detected | See table Z50 | |
| 'Misfire' error detected | See table Z53 | |||
| 'Catalytic converter' error detected | See table Z55 | |||
| 'Upstream Lambda signal' error detected | See table Z56 | |||
| 'Downstream Lambda signal' error detected | See table Z58 | |||
| Another error dected in the control unit | Continue following the instructions for the diagnostic equipment. | |||
| Lack of dialogue with the control unit | Restore the connection between the engine management control unit and the diagnostic connector | |||
| 2 | ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
Using the diagnostic equipment (Examiner or other iinstruments) carry out active diagnosis on the:
| Continue to Step 3 | Connections faulty | Restore the connection of the injectors and the solenoid with the control unit | |
| Solenoid valve faulty | Replace the solenoid valve Op. 1080E28 | |||
| Injector faulty | Replace injector Op. 1056B70 | |||
| 3 | UPSTREAM LAMBDA SENSOR CHECK | All OK | Problems met | Operation |
| Check that the upstream Lambda sensor is working properly. | Continue to Step 4 | Lambda sensor faulty | Replace the Lambda sensor Op. 1080B94 | |
| 4 | DOWNSTREAM LAMDBA SENSOR CHECK | All OK | Problems met | Operation |
| Check that the downstream Lambda sensor is working properly. | Continue to Step 5 | Lambda sensor faulty | Replace the Lambda sensor Op. 1080B95 | |
| 5 | CHECKING AIR CIRCUIT | All OK | Problems met | Operation |
| Check the condition of the air supply circuit | Continue to Step 6 | Circuit component damaged | Replace the component involved | |
| 6 | CHECK ON FUEL PRESSURE | All OK | Problems met | Operation |
| Check the fuel supply pressure Op. 0510C10 | Continue to Step 7 | Pressure not correct | Replace the fuel pupm | |
| 7 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | ||