Workshop Manuals Factory service & repair Lancia
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Lancia Ypsilon Factory Service Manual (2003-2011)22 · Fault diagnosis
22 · Diagnostics

Catalyzer error

Make
Lancia
Model
Ypsilon Factory Service Manual
Year
2003–2011
Section
Examiner › Catalyzer error
Fault diagnosisCatalyzer error

CATALYZER ERROR

1.2 8v, 1.2 16v, 1.4 16v

The diagnostic equipment signals the following error: Catalyzer

Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation

Connect the diagnostic equipment (Examiner or Examiner Plus) and record the errors and environmental parameters.

Check for the 'Catalyzer' error only

End of diagnosisThe 'Upstream Lambda signal' error is presentContinue according to the instructions for the See table Z56 UPSTREAM LAMBDA SENSOR SIGNAL ERROR
The 'Mixture strength' error is presentContinue according to the instructions for the See table Z50 MIXTURE STRENGTH ERROR
'Misfire' error presentContinue according to the instructions for the See table Z53 MISFIRE ERROR
The 'Downstream Lambda signal' error is presentContinue according to the instructions for the See table Z58 DOWNSTREAM LAMBDA SENSOR SIGNAL ERROR
The 'Catalyzer' error only is presentContinue to Step 1
Other errors are present

Identify and eliminate the cause of the anomaly.

Continue to Step 5

1EXHAUST SYSTEM LEAKS CHECKAll OKProblems metOperation

Check the exhaust system, visually and by listening, from the cylinder head outlet to the downstream Lambda sensor.

Check that there are no leaks

Continue to Step 2There are leaks

Restore the correct seal for the exhaust system, if necessary, replace the components involved.

Continue to Step 5

2ROAD TEST TO CHECK MIXTURE STRENGTHAll OKProblems metOperation

Road test the vehicle and check the mixture strength in the 1st and 2nd closed loops using the diagnostic equipment.

Check that the activation is correct

Continue to Step 3The 1st closed loop activation is not correctContinue according to the instructions for the See table Z56 UPSTREAM LAMBDA SENSOR SIGNAL ERROR
The 2nd closed loop activation is not correctContinue according to the instructions for the See table Z58 DOWNSTREAM LAMBDA SENSOR SIGNAL ERROR
3CHECKING INTAKE AND EXHAUST SYSTEM SEALAll OKProblems metOperation
Check the exhaust system visually and by listening, to check that there are no leaks from the cylinder head outlet to the upstream lambda sensorContinue to Step 4Seal not correct

Restore the correct seal for the system, if necessary, replace the components involved.

Continue to Step 5

4REPLACING THE CATALYZERAll OKProblems metOperation
Replace the catalyzer Op. 1080B62Continue to Step 5
5ERROR CANCELLING AND CHECKINGAll OKProblems metOperation

Use a tester to cancel the errors in the control unit.

Road test the vehicle and check that the error does not occur again

Continue to Step 6The fault persists, it is the first time that this step has been reached and the catalyzer has not yet been replacedContinue to Step 0
The fault persists, but it is the second time that this step has been reached or the catalyzer has already been replacedContact Technical Support for further information on the problem
6CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosis