Upstream lambda sensor signal error
- Make
- Lancia
- Model
- Ypsilon Factory Service Manual
- Year
- 2003–2011
- Section
- Examiner › Upstream lambda sensor signal error
UPSTREAM LAMBDA SENSOR SIGNAL ERROR
The diagnostic equipment signals the following error: Upstream Lambda signal
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
Connect the diagnostic equipment (Examiner or Examiner Plus) and record the errors and environmental parameters. Check for the 'Upstream Lambda signal' error only | End of diagnosis | Only the 'Upstream Lambda signal', 'Mixture strength', 'Misfire', 'Catalyzer' and/or 'Downstream Lambda signal' errors are present | Continue to Step 1 | |
| Other errors are present | Identify and eliminate the cause of the problem Continue to Step 8 | |||
| 1 | ERROR DETAIL CHECK | All OK | Problems met | Operation |
Check the detail of the 'Upstream Lambda signal' error In particular, check that it is not 'Open circuit or short circuit to earth' | Continue to Step 3 | The detail is 'Signal not plausible' | Continue according to the instructions for the See table Z57 UPSTREAM LAMBDA SENSOR SIGNAL ERROR | |
| The detail is 'Open circuit or short circuit to earth' | Continue to Step 2 | |||
| 2 | INTAKE AND EXHAUST SYSTEM LEAKAGE CHECK | All OK | Problems met | Operation |
Check the exhaust system visually and by listening. In particular, check that there are no leaks before the upstream Lambda sensor | Continue to Step 3 | There are leaks | Eliminate the leaks from the exhaust system, if necessary, replace the components involved | |
| 3 | UPSTREAM LAMBDA SENSOR SWITCHING CHECK | All OK | Problems met | Operation |
Use a tester to cancel the errors in the control unit. Start the engine, let it warm up and check the activation of the 1st loop mixture strength check using the diagnostic equipment (or, alternatively, the switching of the upstream Lambda signal) | Continue to Step 4 | The activation does not take place (or the signal does not switch) | Continue to Step 6 | |
| 4 | LAMBDA SENSOR WIRING CHECK | All OK | Problems met | Operation |
| Check the upstream Lambda sensor wiring, checking that there are no false contacts See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT | Continue to Step 5 | There are false contacts | Restore correct connections. If necessary, replace the defective components Continue to Step 8 | |
| 5 | ECU SOFTWARE CHECK | All OK | Problems met | Operation |
| Using the FIAT documentation, check that the engine management software calibration is updated | Continue to Step 8 | The control unit does not have updated software setting | Reprogramme the engine management control unit. Continue to Step 8 | |
| 6 | LAMBDA SENSOR/ECU INPUT WIRING CHECK | All OK | Problems met | Operation |
| Check the wiring for the upstream Lambda sensor intake circuit in the ECU, checking that there are no short circuits to the supply or to earth, open circuits or false contacts See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT | Continue to Step 7 | There are faulty connections | Restore correct connections. If necessary, replace the defective components Continue to Step 8 | |
| 7 | REPLACING UPSTREAM LAMBDA SENSOR | All OK | Problems met | Operation |
| Replace the upstream Lambda sensor Op. 1080B60 | Continue to Step 8 | |||
| 8 | ERROR CANCELLING AND CHECKING | All OK | Problems met | Operation |
Use a tester to cancel the errors in the control unit. Road test the vehicle and check that the error does not occur again | Continue to Step 9 | The fault persists, it is the first time that this step has been reached and the Lambda sensor has not yet been replaced | Continue to Step 0 | |
| The fault persists, but it is the second time that this step has been reached, or the Lambda sensor has already been replaced | Contact Technical Support for further information on the problem | |||
| 9 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | |||
The diagnostic equipment signals the following error: Upstream Lambda signal
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
Connect the diagnostic equipment (Examiner or Examiner Plus) and record the errors and environmental parameters. Check for the 'Upstream Lambda signal' error only | End of diagnosis | Only the 'Upstream Lambda signal', 'Mixture strength', 'Misfire', 'Catalyzer' and/or 'Downstream Lambda signal' errors are present | Continue to Step 1 | |
| Other errors are present | Identify and eliminate the cause of the problem Continue to Step 8 | |||
| 1 | ERROR DETAIL CHECK | All OK | Problems met | Operation |
Check the detail of the 'Upstream Lambda signal' error In particular, check that it is not 'Below minimum limit' | Continue to Step 3 | The detail is 'Above upper limit' with error P0133, P0139 and/or P1133 | Continue according to the instructions for the See table Z57 UPSTREAM LAMBDA SENSOR SIGNAL ERROR | |
| The detail is 'Below lower limit' with error P0139 and/or P1133 | Continue according to the instructions for the See table Z57 UPSTREAM LAMBDA SENSOR SIGNAL ERROR | |||
| The detail is 'Below lower limit' with error P0130 and/or P0136 | Continue to Step 2 | |||
| 2 | INTAKE AND EXHAUST SYSTEM LEAKAGE CHECK | All OK | Problems met | Operation |
Check the exhaust system visually and by listening. In particular, check that there are no leaks before the upstream Lambda sensor | Continue to Step 3 | There are leaks | Eliminate the leaks from the exhaust system, if necessary, replace the components involved | |
| 3 | UPSTREAM LAMBDA SENSOR SWITCHING CHECK | All OK | Problems met | Operation |
Use a tester to cancel the errors in the control unit. Start the engine, let it warm up and check the activation of the 1st loop mixture strength check using the diagnostic equipment (or, alternatively, the switching of the upstream Lambda signal) | Continue to Step 4 | The activation does not take place (or the signal does not switch) | Continue to Step 6 | |
| 4 | LAMBDA SENSOR WIRING CHECK | All OK | Problems met | Operation |
| Check the upstream Lambda sensor wiring, checking that there are no false contacts See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT | Continue to Step 5 | There are false contacts | Restore correct connections. If necessary, replace the defective components Continue to Step 8 | |
| 5 | ECU SOFTWARE CHECK | All OK | Problems met | Operation |
| Using the FIAT documentation, check that the engine management software calibration is updated | Continue to Step 8 | The control unit does not have updated software setting | Reprogramme the engine management control unit. Continue to Step 8 | |
| 6 | LAMBDA SENSOR/ECU INPUT WIRING CHECK | All OK | Problems met | Operation |
| Check the wiring for the upstream Lambda sensor intake circuit in the ECU, checking that there are no short circuits to the supply or to earth, open circuits or false contacts See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT | Continue to Step 7 | There are faulty connections | Restore correct connections. If necessary, replace the defective components Continue to Step 8 | |
| 7 | REPLACING UPSTREAM LAMBDA SENSOR | All OK | Problems met | Operation |
| Replace the upstream Lambda sensor Op. 1080B60 | Continue to Step 8 | |||
| 8 | ERROR CANCELLING AND CHECKING | All OK | Problems met | Operation |
Use a tester to cancel the errors in the control unit. Road test the vehicle and check that the error does not occur again | Continue to Step 9 | The fault persists, it is the first time that this step has been reached and the Lambda sensor has not yet been replaced | Continue to Step 0 | |
| The fault persists, but it is the second time that this step has been reached, or the Lambda sensor has already been replaced | Contact Technical Support for further information on the problem | |||
| 9 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | |||
The diagnostic equipment signals the following error: Upstream Lambda signal (slow)
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
Connect the diagnostic equipment (Examiner or Examiner Plus) and record the errors and environmental parameters. Check for the 'Upstream Lambda signal (slow)' error only | End of diagnosis | The 'Upstream Lambda signal' error is present | Continue according to the instructions for the See table Z56 UPSTREAM LAMBDA SENSOR SIGNAL ERROR | |
| Only the 'Upstream Lambda signal (slow)', 'Mixture strength', 'Misfire', 'Catalyzer' and/or 'Downstream Lambda signal' errors are present | Continue to Step 1 | |||
| Other errors are present | Identify and eliminate the cause of the anomaly. Continue to Step 3 | |||
| 1 | SENSOR CHECK | All OK | Problems met | Operation |
Visually inspect:
| Continue to Step 2 | Lambda sensor fitted incorrectly | Fit the Lambda sensor correctly Op. 1080B60 Continue to Step 3 | |
| Terminals corroded | Replace faulty components Continue to Step 3 | |||
| Wiring faulty | Restore correct connections. If necessary, replace the faulty components See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT Continue to Step 3 | |||
| 2 | REPLACING UPSTREAM LAMBDA SENSOR | All OK | Problems met | Operation |
Replace the upstream Lambda sensor. Op. 1080B60 Search for the cause of the pollution in the sensor. The probable causes are:
| Continue to Step 3 | Use of contaminated petrol | Clean the tank Op. 1040A24and introduce suitable quality fuel. Continue to Step 3 | |
| Engine oil leaks detected | Continue according to the instructions for the See table X12 ENGINE OIL LEAKS | |||
| 3 | ERROR CANCELLING AND CHECKING | All OK | Problems met | Operation |
Use a tester to cancel the errors in the control unit. Road test the vehicle and check that the error does not occur again | Continue to Step 4 | The fault persists, it is the first time that this step has been reached and the Lambda sensor has not yet been replaced | Continue to Step 0 | |
| The fault persists, but it is the second time that this step has been reached or the Lambda sensor has already been replaced | Contact Technical Support for further information on the problem | |||
| 4 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | |||
Parts & tools for this job Staging For 2003 Lancia Ypsilon
- PARTOxygen sensorSearch: Lancia Ypsilon 2003 oxygen sensor
- TOOLOxygen sensor socketSearch: oxygen sensor socket
- TOOLOBD2 scannerSearch: OBD2 scanner
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.