Alarm siren not working
- Make
- Fiat
- Model
- Multipla Factory Service Manual
- Year
- 1998–2010
- Section
- Alarm › Alarm siren not working
Fault diagnosisAlarm siren not working
ALARM SIREN NOT WORKING
When the alarm is operated the siren does not emit auditory signals
The auditory signals may or may not be activated, according to the various country modes (see DESCRIPTION AND OPERATION: 5580E anti-theft device).
| Results of the tests | ||||
| 1 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
|---|---|---|---|---|
Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socket Check, in order:
| Continue to Step 2 | Error detected in the control unit or receiver | Continue according to the instructions for the diagnostic equipment | |
| Dialogue failure for diagnostic equipment between the control unit and the receiver | Restore the connection between the control unit and the diagnostic connector ( See E7015 ALARM). | |||
| 2 | ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| With the diagnostic equipment (Examiner or other instruments) carry out the active diagnosis of the operation of the siren | Continue to Step 3 | Siren not activated | Check and, if necessary, replace the alarm control unit Op. 5580E46. | |
| 3 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Search for the fault starting from another symptom' | |
Parts & tools for this job Staging For 1998 Fiat Multipla
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLSocket setSearch: socket set metric
- BOOKHaynes manualSearch: Haynes manual Fiat Multipla
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.