01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Alfa Romeo 159 Factory Service Manual (2005-2011)20 · Wiring diagrams and electrical functions
20 · Electrical

Additional heater - description

Make
Alfa Romeo
Model
159 Factory Service Manual
Year
2005–2011
Section
Climate control system › Additional heater - description
Wiring diagrams and electrical functionsAdditional heater - description

ADDITIONAL HEATER - DESCRIPTION

1.9 JTD 8V, 1.9 JTD 16V, 2.4 JTD 20V · Automatic Air Conditioning, Manual Air Conditioning

DESCRIPTION

The vehicle climate control system is insufficient via the heater unit when the engine is cold, especially for diesel engines which take longer to warm up.

On these versions there is also an additional heating system which is activated when the engine is first running, depending on the temperature of the engine coolant.

The system consists of an additional heating device, located inside the heater unit: this device contains two resistances (PTC1 - 300 W and PTC2 - 600 W).

The operation of the resistances is controlled by the climate control system control unit which operates either just one of them or both thereby providing gradual heating with a maximum power of 900 W according to a control unit that depends on:

- the temperature of the engine coolant (about 60°C);

- the engine speed (which should be above a 700 rpm);

- the battery voltage (which should not go down below 12.2 V).

For more details

See descriptions 5040 AIR CONDITIONING CASING AND COMPONENTS

The power supply for one, two or three resistances is operated by means of two relays located on the actual heater unit:

- 1. Level: activated by the first relay (300W);

- 2. Level: activated by the second relay (600W);

- 3. Level: activated by both relays (900W)

The power supply line is protected by two MIDI maxi fuses located in a special additional fuse box at the side of the battery.