Parking brake failure warning light on
- Make
- Alfa Romeo
- Model
- 159 Factory Service Manual
- Year
- 2005–2011
- Section
- Instrument panel › Parking brake failure warning light on
PARKING BRAKE FAILURE WARNING LIGHT ON
The handbrake/brake fluid warning light remains on with the handbrake released
| 0 | PRELIMINARY CHECKS | All OK | Problems encountered | Operation |
|---|---|---|---|---|
Check that the ABS warning light comes on and goes out during the initial test Connect the diagnostic equipment and check the following at the CAN INFORMATION: - No control units inactive - No faulty control units - No control units with faulty CAN line | Move on to Step 5 | The ABS warning light also remains on | Proceed as instructed in the | |
| Fault on CAN network | Continue following the instructions for the diagnostic equipment | |||
| Communication impossible with the Body Computer | Move on to Step 2 | |||
| 1 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Keeping the diagnostic equipment connected, check the plausibility of the brake fluid level parameter at the Body Computer Node | Move on to Step 4 | The parameter is not plausible | Replace body computer | |
| Impossible to connect to the Body Computer control unit. | Move on to Step 2 | |||
| 2 | ELECTRICAL POWER SUPPLY CHECK | All OK | Problems encountered | Operation |
| Check the electricity supply to the Body Computer Node is correct | Move on to Step 3 | Fault in positive electrical supply and/or earth | Replace the defective component (in the case of a fuse, find out what caused it to blow) | |
| 3 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Using the diagnostic equipment, check the possibility of connection to the Body Computer Node | Move on to Step 1 | Impossible to connect to the Body Computer control unit. | Replace Body Computer | |
| 4 | CHECK ON CORRECT OPERATION | All OK | Problems encountered | Operation |
| Check that the fault is no longer present | End of diagnosis | The fault persists | Move on to Step 5 | |
| 5 | BRAKE FLUID LEVEL CHECK | All OK | Problems encountered | Operation |
| Check that the brake fluid level is not low | Move on to Step 9 | Insufficient brake fluid level | Move on to Step 6 | |
| 6 | BRAKE FLUID LEVEL TOP UP | All OK | Problems encountered | Operation |
| Top up the brake fluid level and check that the warning light goes out | End of diagnosis | The warning light does not go out | Move on to Step 7 | |
| 7 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Keeping the diagnostic equipment connected, check that there are no CAN faults at the BRAKE NODE | Move on to Step 8 | Fault on C-CAN network | Move on to Step 14 | |
| 8 | ELECTRICAL SYSTEM CHECK | All OK | Problems encountered | Operation |
Disconnect the connector from the oil level sensor and check that it is working properly | Move on to Step 9 | Brake fluid level sensor defective | Replace the sensor | |
| 8 | ELECTRICAL SYSTEM CHECK | All OK | Problems encountered | Operation |
Disconnect the connector from the oil level sensor and check that it is working properly | Move on to Step 9 | Brake fluid level sensor defective | Replace the sensor | |
| 9 | ELECTRICAL SYSTEM CHECK | All OK | Problems encountered | Operation |
Check the continuity of the cable from the connector to the Body Computer | Move on to Step 10 | Lead broken | Repair the connection | |
| 10 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Connect the diagnostic equipment and check the plausibility of the handbrake applied parameter at the Body Computer Node | Move on to Step 11 | The parameter is not plausible | Move on to Step 15 | |
| 11 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Connect the diagnostic equipment or keep it connected and check the operation of the brake fluid level warning light in active diagnosis at the Instrument Panel Node | Move on to Step 12 | The warning light does not flash | Replace instrument panel | |
| 12 | ELECTRICAL POWER SUPPLY CHECK | All OK | Problems encountered | Operation |
| Check the electricity supply to the Instrument Panel Node is correct | Move on to Step 13 | Fault in positive electrical supply and/or earth | Replace the defective component (in the case of a fuse, find out what caused it to blow) | |
| 13 | CHECK ELECTRICAL CONNECTIONS | All OK | Problems encountered | Operation |
| Check the wiring between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connected | Move on to Step 14 | Electrical connections not operational | Renew the damaged electrical connections | |
| 14 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Keeping the diagnostic equipment connected, check the plausibility of the brake fluid level parameter at the Body Computer Node | Move on to Step 15 | The parameter is not plausible | Replace body computer | |
| 15 | ELECTRICAL SYSTEM CHECK | All OK | Problems encountered | Operation |
| Check the insulation to earth of the wiring between the Handbrake lever switch and the Body Computer | Move on to Step 16 | Wiring not insulated | Restore wiring | |
| 16 | SWITCH CHECK | All OK | Problems encountered | Operation |
| Check the condition of the switch on the handbrake lever | Move on to Step 17 | Switch defective | Replace the switch | |
| 17 | ACTIVE DIAGNOSIS CHECK | All OK | Problems encountered | Operation |
| With the Examiner in the Instrument Panel Node ambient check that the handbrake warning light is correctly activated in Active Diagnosis. | Move on to Step 19 | The handbrake warning light does not flash | Replace the Instrument Panel | |
| Impossible to connect with the Instrument Panel Node | Move on to Step 18 | |||
| 18 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Using an Examiner check, in Instrument Panel mode, that there are no errors and that the parameters are present | Move on to Step 19 | Presence of errors | Continue following the instructions on the diagnostic instrument | |
| 19 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Using the Examiner check, in the Body Computer ambient, that there are no errors and that the parameter specified varies | Move on to Step 10 | Presence of errors | Continue by following the instructions on the diagnostic instrument | |
| The parameters do not change | Move on to Step 10 | |||
| 20 | CHECK ON CORRECT OPERATION | All OK | Problems encountered | Operation |
| Check that the fault is no longer present | End of diagnosis | The fault persists | Replace Body Computer |
Parts & tools for this job Staging For 2005 Alfa Romeo 159
- PARTBrake padsSearch: Alfa Romeo 159 2005 brake pads
- TOOLBrake bleeder kitSearch: one man brake bleeder kit
- FLUIDBrake fluidSearch: brake fluid
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.