Air bag failure warning light on
- Make
- Alfa Romeo
- Model
- 159 Factory Service Manual
- Year
- 2005–2011
- Section
- Instrument panel › Air bag failure warning light on
AIR BAG FAILURE WARNING LIGHT ON
The brake fluid warning light remains on with the handbrake released.
N.B.: The (negative) brake fluid level signal is sent by the sensor to the Body Computer Node which makes it available via the B-CAN to the Instrument Panel Node.
The Instrument Panel Node lights up the dedicated warning light and displays the insufficient brake fluid level message; if the warning light is faulty, the appropriate message is displayed.
| 0 | PRELIMINARY CHECKS | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
|---|---|---|---|---|
Connect the EXAMINER diagnostic equipment and check the following at the CAN INFORMATION:
| Move on to Step 1 | 1. Fault on CAN network | 1. Continue following the instructions for the diagnostic equipment | |
| 2. Impossible to converse with the Body Computer | 2. Move on to Step 2 | |||
| 1 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Keeping the Examiner connected, check the plausibility of the brake fluid level parameter at the Body Computer Node | Move on to Step 4 | 1.The parameter is not plausible | 1.Replace body computer | |
| 2.Impossible to connect to the Body Computer control unit | 2.Move on to Step 2 | |||
| 2 | ELECTRICAL POWER SUPPLY CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check that the electrical power supply for the Body Computer Node is correct | Move on to Step 3 | Electric power supply positive and/or earth faulty | Replace defective component (in the case of a fuse, find out what caused it to blow). | |
| 3 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Using the Examiner, check whether it is possible to connect to the Body Computer Node. | Move on to Step 4 | Impossible to connect to the Body Computer control unit | Replace Body Computer | |
| 4 | CHECK ON CORRECT OPERATION | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check that the fault is no longer present | End of diagnosis | The fault persists | Move on to Step 5 | |
| 5 | BRAKE FLUID LEVEL CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check that the brake fluid level is not low | Move on to Step 9 | Insufficient brake fluid level | Move on to Step 6 | |
| 6 | BRAKE FLUID LEVEL TOP UP | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Top up the brake fluid level and check that the warning light goes out | End of diagnosis | The warning light does not go out | Move on to Step 7 | |
| 7 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Keeping the diagnostic equipment connected, check that there are no CAN faults at the BRAKE NODE | Move on to Step 8 | Fault on C-CAN | Move on to Step 13 | |
| 8 | ELECTRICAL SYSTEM CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Disconnect the connector from the oil level sensor and check that it is working properly | Move on to Step 9 | Brake fluid level sensor defective | Replace the sensor Op. 3330A30 DEVICE SIGNALLING BRAKE FLUID LEVEL - CHECK DEVICE ON TANK - INCLUDES REPLACING CAP AND TOPPING UP LEVEL, IF NECESSARY | |
| 9 | ELECTRICAL SYSTEM CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check the continuity of the cable from the connector to the Body Computer | Move on to Step 10 | Lead broken | Restore the correct connection. | |
| 10 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Connect the Examiner and check that plausibility of the handbrake applied parameter at the Body Computer Node | Move on to Step 11 | The parameter is not plausible | Proceed as instructed by the | |
| 11 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Connect the Examiner or keep it connected and check the operation of the brake fluid level warning light in active diagnosis at the Instrument Panel Node | Move on to Step 12 | The warning light does not flash | Replace instrument panel | |
| 12 | ELECTRICAL POWER SUPPLY CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check that the electrical power supply for the Instrument Panel Node is correct | Move on to Step 13 | Electric power supply positive and/or earth faulty | Replace the defective component (in the case of a fuse, find out what caused it to blow). 13 | |
| 13 | ELECTRICAL CONNECTIONS CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check the electrical connections betwen the Body Computer and the Instrument Panel, in particular that each individual pin is correctly connected. | Move on to Step 14 | Electrical connections not working. | Renew the damaged electrical connections. | |
| 14 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Keeping the Examiner connected, check the plausibility of the brake fluid level parameter at the Body Computer Node | Move on to Step 15 | The parameter is not plausible | Replace body computer | |
| 15 | CHECK ON CORRECT OPERATION | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check that the fault is no longer present | End of diagnosis |
Parts & tools for this job Staging For 2005 Alfa Romeo 159
- TOOLOBD2 scanner with SRSSearch: OBD2 scanner ABS SRS
- TOOLTrim removal tool kitSearch: trim removal tool kit
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.