01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Alfa Romeo 159 Factory Service Manual (2005-2011)08 · Engine
08 · Engine

Preconverter output temperature sensor operation check

Make
Alfa Romeo
Model
159 Factory Service Manual
Year
2005–2011
Section
Emission control system › Preconverter output temperature sensor operation check
EnginePreconverter output temperature sensor operation check

PRECONVERTER OUTPUT TEMPERATURE SENSOR OPERATION CHECK

Check 1080BG

1.9 JTD 8V, 1.9 JTD 16V, 2.4 JTD 20V

STEPCHECK TO BE PERFORMEDRESOLUTION IF THE CHECK IS NOT OK
1Check whether error P2080 - Temperature sensor on preconverter output - is present using the diagnostic equipment

Replace the temperature sensor

Op. 1080B64 CATALYTIC CONVERTER EXCESS TEMPERATURE THERMOCOUPLE - R + R

2

Press the START/STOP button and turn off the engine.

Disconnect the wiring harness connector from the upstream particulate filter temperature (DPF)

Press the START/STOP button.

Check that the voltage across pin 1 and 2 of the sensor

See K189 UPSTREAM PARTICULATE FILTER TEMPERATURE SENSOR (DPF)

is greater than 4.8 V.

Move on to Step 4

Move on to Step 3
3

If faults are found, restore the wiring between the engine control unit and the downstream temperature sensor

See E5070 PARTICLE FILTER SYSTEM

Replace the wiring if necessary

The test can be considered over

Replace the engine management control unit

Op. 1060G80 DIESEL ELECTRONIC INJECTION CONTROL UNIT - .R

4

Press the START/STOP button.

Check that the resistance across pin 1 and 2 of the sensor

See K189 UPSTREAM PARTICULATE FILTER TEMPERATURE SENSOR (DPF)

is between 200 and 600 Ohms

Replace the temperature sensor

Op. 1080B64 CATALYTIC CONVERTER EXCESS TEMPERATURE THERMOCOUPLE - R + R

5

Replace the engine management control unit

Op. 1060G80 DIESEL ELECTRONIC INJECTION CONTROL UNIT - .R

Parts & tools for this job Staging For 2005 Alfa Romeo 159