Relay for battery disconnection system - r.r.
- Make
- Alfa Romeo
- Model
- 159 Factory Service Manual
- Year
- 2005–2011
- Section
- Current generation › Relay for battery disconnection system - r.r.
RELAY FOR BATTERY DISCONNECTION SYSTEM - R.R.
Removing
- Open the bonnet.
1. Release the retainers (1a) and remove the cover (1b) for the supply box.
1. Undo the nuts.
2. Move the electrical connection for the starter motor.
3. Disconnect the electrical connection.
| Description | Component |
|---|---|
| MAXI FUSE BOX ON BATTERY | See B099 MAXIFUSE BOX ON BATTERY |
4. Release the connection from the retainers.
5. Remove the relay.
Refitting
- Check that the relay is not damaged.
- Position the relay.
- Connect the connection to the retainers.
- Connect the electrical connection.
- Position the electrical connection for the starter motor.
- Tighten the nuts.
- Place the supply box cover in position and attach the retainers.
- Close the bonnet.