01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Lancia Ypsilon Factory Service Manual (2003-2011)22 · Fault diagnosis
22 · Diagnostics

Climate control recirculation automatic mode not working

Make
Lancia
Model
Ypsilon Factory Service Manual
Year
2003–2011
Section
Climate control › Climate control recirculation automatic mode not working
Fault diagnosisClimate control recirculation automatic mode not working

CLIMATE CONTROL RECIRCULATION AUTOMATIC MODE NOT WORKING

The recirculation is not closed in automatic mode when there is pollutaion.

Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation

Check:

  • that the flap works when the recirculation button is pressed
Continue to Step 1Motor not workingContinue to Step 2
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Connect the examiner and check for errors at the climate control node.

Carry out the recirculation motor test in active diagnosis

If it is not activated, check the recirculation motor wiring

Continue to Step 2Faulty wiringRenew the wiring
2CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Connect the Examiner diagnostic equipment:

  • check that the recirculation flap is working properly in automatic mode by selecting active diagnosis and carrying out the 'pollution sensor test'.
  • If the result is negative, carry out See Test 5040DD Check on pollution sensor signal
Continue to Step 3Passenger compartment air pollution sensor defectiveReplace sensor
Passenger compartment air pollution sensor defectiveRenew the wiring
3CHECK ON CORRECT OPERATIONAll OKProblems metOperation

Check that the recirculation flap is working properly by carrying out the 'pollution sensor test' again with the Examiner in Active Diagnosis

Check that the fault is no longer present

End of diagnosisFault persistsReplace the climate control system control unit