Fault diagnosisClimate control recirculation not working
CLIMATE CONTROL RECIRCULATION NOT WORKING
When the button in the switch panel is pressed, the recirculation function does not work.
| Results of the tests | ||||
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
|---|---|---|---|---|
| Connect the Examiner and check for errors at the air recirculation motor. | Continue to Step 2 | Air recirculation motor not working | Continue to Step 3 | |
| 2 | CHECKING USING TESTER | All OK | Problems met | Operation |
| Keep the Examiner connected and check air recirculation motor operation by means of active diagnosis | Continue to Step 7 | Air recirculation motor not working | Continue to Step 3 | |
| 3 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation |
| Check the continuity/insulation of the electrical connection between the climate control Node and the air recirculation motor See E6020 AIR CONDITIONING | Continue to Step 4 | Electrical conection broken or not insulated. | Restore electrical connection continuity/insulation. See E6020 AIR CONDITIONING | |
| 4 | RECIRCULATION MOTOR OPERATION CHECK | All OK | Problems met | Operation |
| Disconnect the electrical connector, air recirculation motor side, and check for a control signal from the climate control system node See E6020 AIR CONDITIONING | Continue to Step 5 | Signal absent | Continue to Step 7 | |
| 5 | CHECKING RECIRCULATION MOTOR FLAP | All OK | Problems met | Operation |
| Check that the air recirculation motor flap moves through its travel without sticking. | Continue to Step 6 | Flap blocked or damaged | Release the air recirculation motor flap from its block or replace the flap if damaged. | |
| 6 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present. | End of diagnosis | Fault persists | Change the air recirculation motor | |
| 7 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Change the climate control system node. | |