01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Lancia Ypsilon Factory Service Manual (2003-2011)22 · Fault diagnosis
22 · Diagnostics

Climate control recirculation not working

Make
Lancia
Model
Ypsilon Factory Service Manual
Year
2003–2011
Section
Climate control › Climate control recirculation not working
Fault diagnosisClimate control recirculation not working

CLIMATE CONTROL RECIRCULATION NOT WORKING

When the button in the switch panel is pressed, the recirculation function does not work.

Results of the tests
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the Examiner and check for errors at the air recirculation motor.Continue to Step 2Air recirculation motor not workingContinue to Step 3
2CHECKING USING TESTERAll OKProblems metOperation
Keep the Examiner connected and check air recirculation motor operation by means of active diagnosisContinue to Step 7Air recirculation motor not workingContinue to Step 3
3ELECTRICAL CIRCUIT CHECKAll OKProblems metOperation
Check the continuity/insulation of the electrical connection between the climate control Node and the air recirculation motor See E6020 AIR CONDITIONINGContinue to Step 4Electrical conection broken or not insulated.Restore electrical connection continuity/insulation. See E6020 AIR CONDITIONING
4RECIRCULATION MOTOR OPERATION CHECKAll OKProblems metOperation
Disconnect the electrical connector, air recirculation motor side, and check for a control signal from the climate control system node See E6020 AIR CONDITIONINGContinue to Step 5Signal absentContinue to Step 7
5CHECKING RECIRCULATION MOTOR FLAPAll OKProblems metOperation
Check that the air recirculation motor flap moves through its travel without sticking.Continue to Step 6Flap blocked or damagedRelease the air recirculation motor flap from its block or replace the flap if damaged.
6CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer present.End of diagnosisFault persistsChange the air recirculation motor
7CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosisFault persistsChange the climate control system node.