PASSENGER SIDE TEMPERATURE ADJUSTMENT DOES NOT WORK
When the required temperature is set on the passenger side, no air flow is felt at the required temperature
| Results of the tests | ||||
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
|---|---|---|---|---|
| Connect the Examiner, check for errors on the passenger side air mixing motor | Continue to Step 2 | Mixed air motor error. | Continue to Step 3 | |
| 2 | CHECKING USING TESTER | All OK | Problems met | Operation |
| Keep the Examiner connected and check the operation of the mixed air operation by means of active diagnosis. | Continue to Step 7 | Air mixing motor does not work | Continue to Step 3 | |
| 3 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation |
| Check continuity/insulation of the electrical connection between climate control Node and passenger side air mixing motor See E6020 AIR CONDITIONING | Continue to Step 4 | Electrical conection broken or not insulated. | Restore electrical connection continuity/insulation. See E6020 AIR CONDITIONING | |
| 4 | CHECKING AIR MIXING MOTOR OPERATION | All OK | Problems met | Operation |
| Check the presence of the control signal coming from the climate control node See E6020 AIR CONDITIONING | Continue to Step 5 | No signal | Continue to Step 7 | |
| 5 | AIR MIXING MOTOR FLAP CHECK | All OK | Problems met | Operation |
| Check that the air mixing motor flap moves through its travel without sticking. | Continue to Step 6 | Flap blocked or damaged | Release the air recirculation motor flap from its block or replace the flap if damaged. | |
| 6 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present. | End of diagnosis | Fault persists | Change the passenger side air mixing motor Op. 5040D86 | |
| 7 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Change the climate control system node Op. 5040D18 | |
‹ Prev Climate control recirculation automatic mode not workingNext › Windscreen misting with the formation of condensation
Parts & tools for this job Staging For 2003 Lancia Ypsilon
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Lancia Ypsilon 2003 cabin filter
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.