CLIMATE CONTROL NOT COOLING
The fan works properly and sends air into the interior compartment in accordance with set flow patterns, but this air remains at the external temperature and is not cooled.
Cooling circuit activation enablement is controlled by the climate control and engine management control units. So if the air conditioning does not cool under particular conditions, this is correct.
| Results of the tests | ||||
| 0 | PRELIMINARY CHECK | All OK | Problems met | Operation |
|---|---|---|---|---|
| Connect the climate control system to the repressurizing equipment and check the system pressure See Test 5040B CHECK ON OPERATION OF AIR CONDITIONING SYSTEM (PRESSURES) | Continue to Step 1 | Pressure not correct | Eliminate leaks and top up climate control system Op. 5040A10 | |
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
Connect the examiner and check for errors at the climate control node:
| Continue to Step 3 | Error in air mixing motors. | Continue to Step 2 | |
| Error in air mixing motors. | Continue to Step 2 | |||
| Error in air mixing motors. | Continue to Step 2 | |||
| 2 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation |
Check continuity/insulation of electrical connection:
| Continue to Step 8 | Electrical conection broken or not insulated. | Restore electrical connection continuity/insulation. See E6021 COMPRESSOR ENGAGEMENT | |
| 3 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
Keeping the Examiner diagnostic equipment connected, check:
| Continue to Step 6 | The relay is not activated and the coupling is not activated. | Continue to Step 4 | |
| The relay is activated but the coupling is not activated. | Continue to Step 5 | |||
| Solar sensor defective | Replace the sensor | |||
| 4 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation |
| Check continuity/insulation of compressor activation relay electrical circuit See E6021 COMPRESSOR ENGAGEMENT | Continue to Step 5 | Electrical connections broken or not insulated | Restore electrical connection continuity/insulation. | |
| Compressor engagement relay faulty. | Change compressor activation relay | |||
| 5 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation |
| Check the continuity/insulation of the compressor electric power circuit See E6021 COMPRESSOR ENGAGEMENT | Continue to Step 6 | Electrical connections broken or not insulated | Restore electrical connection continuity/insulation. | |
| Electromagnetic coupling fault. | Replace the compressor complete with coupling Op. 5040A20 | |||
| 6 | LINKAGE CHECK | All OK | Problems met | Operation |
| Check air duct opening motor linkage. | Continue to Step 7 | Linkage incorrectly connected. | Restore correct fastening of linkage to motor. | |
| Linkage damaged | Replace the linkage. | |||
| 7 | COMPRESSOR ENGAGEMENT CHECK | All OK | Problems met | Operation |
| Check compressor is properly activated by See Test 5040BC Check activation/deactivation of climate control compressor from linear sensor | Continue to Step 9 | Compressor does not activate | Check electrical connection and restore continuity/insulation if necessary. See E6020 AIR CONDITIONING | |
| 8 | CHECKING CORRECT OPERATION USING TESTER | All OK | Problems met | Operation |
Check for persistent errors:
| End of diagnosis | Left air mixing motor error | Replace the left mixed air motor. Op. 5040D84 | |
| Right air mixing motor error. | Replace the right mixed air motor. Op. 5040D86 | |||
| Treated air sensor error. | Replace the damaged treated air sensor Op. 5010D28 | |||
| Frost sensor error. | Change the frost sensor Op. 5040A22 | |||
| 9 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Replace the linear sensor and check that the fault is no longer present. | End of diagnosis | Fault persists | Continue to Step 10 | |
| 10 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Change the climate control system node Op. 5040D18 | |