Fault diagnosisClimate control too cold
CLIMATE CONTROL TOO COLD
The control button operates the passenger compartment air fan normally, but the temperature of the air is not correct.
| Results of the tests | ||||
| 0 | PRELIMINARY CHECK | All OK | Problems met | Operation |
|---|---|---|---|---|
| Check that the evaporator air filter is not blocked | Continue to Step 1 | Evaporator air filter blocked | Replace the evaporator filter | |
| 1 | CHECKING SYSTEM PRESSURE | All OK | Problems met | Operation |
| Connect the climate control system to the repressurizing equipment and check the system pressure. See Test 5040A CHECK ON OPERATION OF AIR CONDITIONING SYSTEM (TEMPERATURE) | Continue to Step 2 | System pressure incorrect. Coolant pressure too low or too high | Restore correct system pressure Op. 5040A10restoring the correct coolant level | |
| 2 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
Connect the diagnostic equipment and check for errors:
| Continue to Step 4 | Air mixing motor error. | Continue to Step 3 | |
| Air mixing motor error. | Continue to Step 3 | |||
| Air mixing motor error. | Continue to Step 3 | |||
| 3 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation |
Check continuity/insulation of electrical connection:
| Continue to Step 7 | Electrical conection broken or not insulated. | Restore electrical connection continuity/insulation. | |
| 4 | CHECKING PIPES AND FILTER | All OK | Problems met | Operation |
| Check that high and low pressure pipes and the drier filter for air conditioning system are not blocked. | Continue to Step 5 | Pipe from compressor to condenser blocked. | Change the pipe from compressor to condenser Op. 5040A50 | |
| Pipe from filter to expansion valve blocked. | Change the pipe from filter to expansion valve Op. 5040S54 | |||
| Drier filter blocked and/or damaged. | Replace the filter Op. 5040A44 | |||
| 5 | CONDENSER CHECK | All OK | Problems met | Operation |
| Check that the condenser is not blocked. | Continue to Step 6 | Condenser blocked | Replace the condenser Op. 5040A40 | |
| 6 | EXPANSION VALVE CHECK | All OK | Problems met | Operation |
| Check that the expansion valve is working properly | Continue to Step 8 | Expansion valve stuck closed. | Replace the expansion valve Op. 5040B30 | |
| 7 | CHECKING CORRECT OPERATION USING TESTER | All OK | Problems met | Operation |
Check for persistent errors:
| End of diagnosis | Air mixing motor error | Replace the mixed air motor | |
| Treated air sensor error | Change the treated air sensor Op. 5010D28 | |||
| Frost sensor error | Change the frost sensor Op. 5040A22 | |||
| 8 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Change the climate control system node Op. 5040D18 | |