FAN WILL NOT WORK AT DIFFERENT SPEEDS
The fan motor does not work when the speed selector is used.
| Results of the tests | ||||
| 0 | PRELIMINARY CHECK | All OK | Problems met | Operation |
|---|---|---|---|---|
| Check the electrical connection is properly secured to the fan motor. | Continue to Step 1 | Electrical connection incorrectly connected. | Connect the fan motor electrical connection correctly. | |
| 1 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation |
| Check continuity/insulation of the electrical connection between the fan motor and climate control system node See E6020 AIR CONDITIONING | Continue to Step 2 | Electrical connection broken and not insulated. | Restore electrical connection continuity/insulation. See E6020 AIR CONDITIONING | |
| 2 | CHECKING SPEED SELECTOR | All OK | Problems met | Operation |
| Check the speed selector is working properly. | Continue to Step 3 | Fan motor speed selector malfunction | Change the climate control system node. | |
| 3 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Change the fan motor. | |