01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Ulysse Factory Service Manual (2002-2010)08 · Engine
08 · Engine

Waste gate supercharging pressure adjustment solenoid valve - r.r.

Make
Fiat
Model
Ulysse Factory Service Manual
Year
2002–2010
Section
Engine supercharging system › Waste gate supercharging pressure adjustment solenoid valve - r.r.
EngineWaste gate supercharging pressure adjustment solenoid valve - r.r.

WASTE GATE SUPERCHARGING PRESSURE ADJUSTMENT SOLENOID VALVE - R.R.

Operation 1064B38 · CONTROL/SAFETY DEVICES

2.0 16V JTD, 2.2 16V JTD

Removing

1. Disconnect the electrical connection.

2. Release the vacuum pipes.

3. Undo the retaining nuts.

4. Release and remove the solenoid valve.

WASTE GATE SUPERCHARGING PRESSURE ADJUSTMENT SOLENOID VALVE - R.R.

Refitting

- Place the solenoid valve in position and tighten the fixing nuts.

- Connect the vacuum pipes and the electrical connection.

Parts & tools for this job Staging For 2002 Fiat Ulysse