Workshop Manuals Factory service & repair Fiat
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Fiat Panda Factory Service Manual (2003-2012)23 · Fault diagnosis
23 · Diagnostics

Fuel level gauge not working

Make
Fiat
Model
Panda Factory Service Manual
Year
2003–2012
Section
Instrument panel › Fuel level gauge not working
Fault diagnosisFuel level gauge not working

FUEL LEVEL GAUGE NOT WORKING

With the ignition key in the ON position, the fuel gauge indicator is not working properly or it indicates a different level from what is actually in the tank.

the fuel level message is supplied by the Body Computer Node and is made available to the Instrument Panel Node via the B-CAN; (the Body Computer Node also sends the fuel level sensor error message).

Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation

Check that with the engine started up:

  • The level indicator is not at 0 and the fuel reserve warning light is not flashing
  • There are no error messages at the matrix that can be reconfigured
Continue to Step 2Level indicator at zero and warning light flashingContinue to Step 3
Presence of failure messagesContinue to Step 1
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Connect the diagnostic equipment (Examiner or other instruments) to the Body Computer.

Check the following on the CAN information network:

  • for inactive control units;
  • control unit errors;
  • absence of control unit with error in CAN line
Continue to Step 2Presence of faultsContinue following the instructions for the diagnostic equipment
2CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check the operation of the indicator through active diagnosis.Continue to Step 3The pointer does not moveReplace instrument panel Op. 5560B11
3FUEL LEVEL SENSOR CHECKAll OKProblems metOperation
Check the operation of the fuel level sensor.Continue to Step 4Sensor not workingReplace the fuel pump assembly Op. 1040A70
4ELECTRICAL CIRCUIT CHECKAll OKProblems metOperation
Check the continuity/insulation of the cable between the fuel level sensor and the Body Computer See E4010 INSTRUMENT PANELContinue to Step 5Cables broken or not insulatedRestore continuity or insulation See E4010 INSTRUMENT PANEL
5Continue as instructed by the testerAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosis

Parts & tools for this job Staging For 2003 Fiat Panda

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.