01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Fiat Panda Factory Service Manual (2003-2012)23 · Fault diagnosis
23 · Diagnostics

Rev counter not working

Make
Fiat
Model
Panda Factory Service Manual
Year
2003–2012
Section
Instrument panel › Rev counter not working
Fault diagnosisRev counter not working

REV COUNTER NOT WORKING

With the engine started, the rev counter does not work, or it works irregularly.

The engine rpm message supplied by the Engine Management Control Unit Node via the Body Computer Node is made available to the Instrument Panel Node.

Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation
Check that no failure message is displayed with the engine started upContinue to Step 2There are faults detectedContinue to Step 1
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Connect the diagnostic equipment (Examiner Plus or Smart) to the body computer.

Check the following on the CAN information network:

  • for inactive control units;
  • control unit errors;
  • absence of control unit with error in CAN line
Continue to Step 2Presence of faults in the CAN networkContinue according to the instructions for the diagnostic equipment
Presence of errors at instrument panel nodeContinue to Step 2
2CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the diagnostic equipment (Examiner Plus or Smart) to the diagnostic socket or keep it connected and check that there are no faults at the instrument panel nodeContinue to Step 3For the presence of errors or failed dialogue with the diagnostic equipmentContinue according to the instructions for the diagnostic equipment
3CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Keeping the diagnostic equipment (Examiner) connected to the diagnostic socket, check the operation of the pointer through active diagnosisContinue to Step 4Rev counter is not workingReplace instrument panel Op. 5560B11
4Continue as instructed by the testerAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosis

Parts & tools for this job Staging For 2003 Fiat Panda

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.