Luggage compartment does not open with remote control
- Make
- Alfa Romeo
- Model
- Brera and Spider Factory Service Manual
- Year
- 2005–2010
- Section
- Doors › Luggage compartment does not open with remote control
LUGGAGE COMPARTMENT DOES NOT OPEN WITH REMOTE CONTROL
The boot lid does not open when the remote control is operated.
The opening command for the boot lid is received by the body computer node; the body computer node unlocks the boot lid lock and releases it gently, disabling the alarm (if fitted).
With the "central locking switched off", the boot lid opens activating the electric handle located on the actual boot lid.
In "indepedent boot" mode, the opening of the boot lid is implemented using the remote control or by means of the mechanical key pawl.
| 1 | PRELIMINARY CHECKS | All OK | Problems encountered | Operation |
|---|---|---|---|---|
Check operation is correct using the key and the button on the dashboard. Check the remote control battery is charged | Move on to Step 2 | The boot cannot be opened using the key or from the dashboard | Proceed as instructed in the | |
| Battery not working properly | Replace the battery | |||
| 2 | CHECK REMOTE CONTROL | All OK | Problems encountered | Operation |
| Check the operation of the system using the second remote control. | Move on to Step 3 | The fault persists. | Move on to Step 4 | |
| 3 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Connect the Examiner diagnostic equipment and check that the "defective" remote control is correctly programmed inside the Body Computer Node configuration. | Move on to Step 9 | Remote control not stored in Body Computer Node configuration. | Programme the remote control | |
| 4 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Connect the Examiner diagnostic equipment and check that the remote controls are correctly stored inside the Body Computer Node configuration. | Move on to Step 5 | Remote controls not stored in Body Computer Node configuration. | Programme the remote controls | |
| 5 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Keeping the Examiner diagnostic equipment connected, check, in parameter mode, that individual remote control buttons have been correctly programmed and operate correctly. | Move on to Step 8 | The remote control signals have not been correctly learnt | Move on to Step 6 | |
| 6 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Check that there are no errors using the Examiner diagnostic equipment | Move on to Step 8 | Error detected: RF receiver broken | Move on to Step 7 | |
| 7 | ELECTRICAL CIRCUIT CHECK | All OK | Problems encountered | Operation |
| Check the Body Computer aerial. | Move on to Step 8 | Aerial connector incorrectly connected | Connect the aerial connector properly to the Body Computer Node. | |
| Aerial interrupted. | Replace the RF receiver aerial | |||
| 8 | CHECK ON CORRECT OPERATION | All OK | Problems encountered | Operation |
| Check that the body computer is working properly | End of diagnosis. | Body Computer defective | Replace the Body Computer |
Parts & tools for this job Staging For 2005 Alfa Romeo Brera
- TOOLTrim removal tool kitSearch: trim removal tool kit
- PARTTouch-up paintSearch: Alfa Romeo touch up paint
- PARTPanel clip assortmentSearch: Alfa Romeo panel clips assortment
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.