Fuel flap opening not working
- Make
- Alfa Romeo
- Model
- Brera and Spider Factory Service Manual
- Year
- 2005–2010
- Section
- Doors › Fuel flap opening not working
FUEL FLAP OPENING NOT WORKING
When the doors are opened using the remote control, the fuel filler flap is not released.
| 1 | FUSE CHECK | All OK | Problems encountered | Operation |
|---|---|---|---|---|
Check the condition of the protective fuse | Move on to Step 2 | Fuse blown | Replace the fuse (and find out what could have caused it to blow). | |
| 2 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Connect the diagnostic instrument and check for errors in the body computer node. | Move on to Step 3 | Errors present | Continue as instructed by the diagnostic equipment | |
| 3 | ELECTRICAL CIRCUIT CHECK | All OK | Problems encountered | Operation |
Check the electrical connection of the fuel flap opening pawl. | Move on to Step 4 | Electrical connector on boot lock incorrectly connected | Connect the electrical connector to the boot lock correctly | |
| 4 | ELECTRICAL SIGNAL CHECK | All OK | Problems encountered | Operation |
| Disconnect the fuel flap opening pawl electrical connector and check the signal controlling door opening/closure from the remote control is present. | Move on to Step 5 | Opening control signal missing | Move on to Step 7 | |
| 5 | RELAY CHECK | All OK | Problems encountered | Operation |
| Check the lock motor control relay is operating correctly. | Move on to Step 6 | Relay defective | Replace the defective relay. | |
| 6 | CHECK FUEL FLAP LOCK GEARED MOTOR | All OK | Problems encountered | Operation |
| Check that the fuel flap lock is working properly. | End of diagnosis | Fuel filler flap lock motor defective | Replace the fuel flap lock motor Op. 7025C40 FUEL FILLER FLAP CONTROL MOTOR - R+R AND CHECK LOCK SUPPLY LINE | |
| 7 | ELECTRICAL CIRCUIT CHECK | All OK | Problems encountered | Operation |
Check the electrical connection between the Body Computer Node and the relay | Move on to Step 8 | Connections broken or not insulated | Restore the continuity/insulation of the electrical connection | |
| 8 | CHECK ON CORRECT OPERATION | All OK | Problems encountered | Operation |
| Check that it is working properly | End of diagnosis | The fault persists. | Replace the Body Computer] |
Parts & tools for this job Staging For 2005 Alfa Romeo Brera
- TOOLTrim removal tool kitSearch: trim removal tool kit
- PARTTouch-up paintSearch: Alfa Romeo touch up paint
- PARTPanel clip assortmentSearch: Alfa Romeo panel clips assortment
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.