01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Alfa Romeo Brera and Spider Factory Service Manual (2005-2010)23 · Fault diagnosis
23 · Diagnostics

Fuel flap opening not working

Make
Alfa Romeo
Model
Brera and Spider Factory Service Manual
Year
2005–2010
Section
Doors › Fuel flap opening not working
Fault diagnosisFuel flap opening not working

FUEL FLAP OPENING NOT WORKING

When the doors are opened using the remote control, the fuel filler flap is not released.

1FUSE CHECKAll OKProblems encounteredOperation

Check the condition of the protective fuse

See E3045 BOOT AND FUEL FLAP OPENING

Move on to Step 2Fuse blownReplace the fuse (and find out what could have caused it to blow).
2CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Connect the diagnostic instrument and check for errors in the body computer node.Move on to Step 3Errors presentContinue as instructed by the diagnostic equipment
3ELECTRICAL CIRCUIT CHECKAll OKProblems encounteredOperation

Check the electrical connection of the fuel flap opening pawl.

See E3045 BOOT AND FUEL FLAP OPENING

Move on to Step 4Electrical connector on boot lock incorrectly connected

Connect the electrical connector to the boot lock correctly

See E3045 BOOT AND FUEL FLAP OPENING

4ELECTRICAL SIGNAL CHECKAll OKProblems encounteredOperation
Disconnect the fuel flap opening pawl electrical connector and check the signal controlling door opening/closure from the remote control is present.Move on to Step 5Opening control signal missingMove on to Step 7
5RELAY CHECKAll OKProblems encounteredOperation
Check the lock motor control relay is operating correctly.Move on to Step 6Relay defectiveReplace the defective relay.
6CHECK FUEL FLAP LOCK GEARED MOTORAll OKProblems encounteredOperation
Check that the fuel flap lock is working properly.End of diagnosisFuel filler flap lock motor defective

Replace the fuel flap lock motor

Op. 7025C40 FUEL FILLER FLAP CONTROL MOTOR - R+R AND CHECK LOCK SUPPLY LINE

7ELECTRICAL CIRCUIT CHECKAll OKProblems encounteredOperation

Check the electrical connection between the Body Computer Node and the relay

See E3045 BOOT AND FUEL FLAP OPENING

Move on to Step 8Connections broken or not insulated

Restore the continuity/insulation of the electrical connection

See E3045 BOOT AND FUEL FLAP OPENING

8CHECK ON CORRECT OPERATIONAll OKProblems encounteredOperation
Check that it is working properlyEnd of diagnosisThe fault persists.

Replace the Body Computer]

Op. 5505A32 BODY COMPUTER - R.R