01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Alfa Romeo Brera and Spider Factory Service Manual (2005-2010)23 · Fault diagnosis
23 · Diagnostics

Boot opening/closing not working

Make
Alfa Romeo
Model
Brera and Spider Factory Service Manual
Year
2005–2010
Section
Doors › Boot opening/closing not working
Fault diagnosisBoot opening/closing not working

BOOT OPENING/CLOSING NOT WORKING

When the opening/closing of the luggage compartment is operated using the key, or the opening using the button in the control panel, the boot does not open and does not close

1FUSE AND RELAY CHECKAll OKProblems encounteredOperation

Check the condition of the fuses and relays

See E3045 BOOT AND FUEL FLAP OPENING

Move on to Step 2Components faultyReplace the component (in the case of a fuse, find out what caused it to blow)
2CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Check the boot lid opening/closure in active diagnosisMove on to Step 6The boot will not open/closeMove on to Step 3
3ELECTRICAL CIRCUIT CHECKAll OKProblems encounteredOperation

Check the electrical connection between the body computer node, driver''s door node and boot lock

See E3045 BOOT AND FUEL FLAP OPENING

Move on to Step 4Electrical connector on boot lock incorrectly connectedConnect the electrical connector to the boot lock correctly
Connections broken or not insulated

Restore the continuity/insulation of the electrical connection

See E3045 BOOT AND FUEL FLAP OPENING

4ELECTRICAL SIGNAL CHECKAll OKProblems encounteredOperation
Disconnect the electrical connector for the boot lid lock and check for the opening control signalMove on to Step 5Opening control signal missingMove on to Step 7
5CHECK ON CORRECT OPERATIONAll OKProblems encounteredOperation
Check that the fault is no longer present.End of diagnosis.The fault persists.

Replace the boot lock motor

Op. 7015B70 TAILGATE LOCK MOTOR - R.R AND CHECK LOCK SUPPLY LINE

6CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Press the button in the dashboard and check the driver''s door node to ensure that the status of the boot lid opening button alters while in parameter mode.Move on to Step 8There is no change in statusMove on to Step 7
7ELECTRICAL CIRCUIT CHECKAll OKProblems encounteredOperation

Check the electrical connection between the switch on the console and the driver''s door node

See E3045 BOOT AND FUEL FLAP OPENING

Check that the switch is working properly

Move on to Step 8Connections broken or not insulated

Restore the continuity/insulation of the electrical connection

See E3045 BOOT AND FUEL FLAP OPENING

Switch faulty

Replace the switch on the console

Op. 7015B81 TAILGATE OPENING CONTROL SWITCH - R.R.

8REPLACE THE DRIVER''S DOOR NODEAll OKProblems encounteredOperation

Replace the Driver''s Door Node

Op. 5505A42 CONTROL UNIT (DIGITAL NETWORK NODE) IN DRIVER'S DOOR - R.R.

and check that the fault is no longer present.

End of diagnosis.The fault persists.

Restore the driver''s door node and replace the body computer

Op. 5505A32 BODY COMPUTER - R.R