P0110 - debimeter air temperature signal
- Make
- Alfa Romeo
- Model
- 159 Factory Service Manual
- Year
- 2005–2011
- Section
- Examiner - diesel electronic management › P0110 - debimeter air temperature signal
P0110 - DEBIMETER AIR TEMPERATURE SIGNAL
The diagnostic equipment signals: Error P0110 (Air flow meter temperature signal)
This error is detected if the junction unit inlet voltage (Pin 53) is greater than 4.95 V (positive short circuit) (detail "Beyond the upper limit" or less than 0.05 V (short circuit to earth or break in the circuit) (detail "Below the lower limit"). In this case the junction unit replacement value is 40 °C.
| 1 | SUPERCHARGING TEMPERATURE SENSOR CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
|---|---|---|---|---|
Check that the supercharging temperature sensor is working properly, following the instructions in the | End of diagnosis |