Windscreen misting with the formation of condensation
- Make
- Alfa Romeo
- Model
- 159 Factory Service Manual
- Year
- 2005–2011
- Section
- Climate control › Windscreen misting with the formation of condensation
WINDSCREEN MISTING WITH THE FORMATION OF CONDENSATION
On vehicles equipped with a windscreen demisting sensor, it does not work and the windscreen does not demist with the air conditioning on when there is condensation.
| 1 | CHECK ON CORRECT OPERATION OF SENSOR | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
|---|---|---|---|---|
| Check that the demisting sensor lens in the windscreen is not obstructed by foreign bodies or that it is not dirty or marked and that the windscreen is not dirty. | Move on to Step 2 | 1.Demisting sensor lens obscured by foreign bodies. | 1. Remove the foreign bodies from the sensor. | |
| 2. Demisting sensor lens dirty. | 2. Clean the sensor lens. | |||
| 3. Demisting sensor lens scratched. | 3. Replace the demisting sensor Op. 5010D36 DEMISTING SENSOR R R FOLLOWING ELECTRICAL CIRCUIT CHECK | |||
| 4. Windscreen dirty. | 2. Clean the windscreen. | |||
| 2 | CHECK THAT THE PROXY HAS BEEN CARRIED OUT FOR THE SYSTEM | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Connect the Examiner diagnostic equipment and check that the Proxy has been carried out for the system to recognize the sensor. | Move on to Step 3 | Proxy not carried out for the system to recognize the sensor. | Carry out the Proxy for the system. | |
| 3 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Connect the Examiner diagnostic equipment and check that there are no errors at the windscreen demisting sensor. If the result is negative, carry out the | Move on to Step 4 | 1.Error in the demisting sensor: 0% or 100% according to the | 1. Move on to Step 5 | |
2. Error in the demisting sensor: 90% or 80% according to the | 2. Move on to Step 6 | |||
3. Error in the demisting sensor: 10% according to the | 3. Replace the demisting sensor Op. 5010D36 | |||
| 4 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Keeping the Examiner diagnostic equipment connected, check:
| Move on to Step 8 | 1. Error at climate control node. | 1. Move on to Step 5. | |
| 2. Short circuit to earth error at the distribution actuator. | 2. Check that the Lin Bus cables are not caught between the metal parts (pay special attention to the gearbox bolts) and move on to Step 8. | |||
| 3. Short circuit to +12V error at the distribution actuator. | 3. Check that the Lin Bus cables are not caught between the metal parts (pay special attention to the gearbox bolts) and move on to Step 8. | |||
| 4. Mechanical interference/stuck error. | 4. Move on to Step 10. | |||
| 5 | CHECKS USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Keeping the Examiner diagnostic equipment connected, check the correct operation of the air mixture actuator through active diagnosis | Move on to Step 6. | Air mixture actuator not working | Move on to Step 8. | |
| 6 | CHECK ON DEMISTING SENSOR ELECTRICAL CONNECTIONS | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check whether the windscreen demisting sensor electrical wiring connections are loose or damaged, disconnect/reconnect the wiring. Check the continuity/insulation of the sensor electrical wiring. | Move on to Step 7 | 1. Electrical connections loose or damaged. | 1. Restore correct wiring. | |
| 2. Sensor wiring broken or short circuited. | 2. Restore correct wiring. | |||
| 7 | CHECK ON THE CORRECT INSTALLATION OF THE DEMISTING SENSOR | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check that the demisting sensor is correctly positioned in its housing. | Move on to Step 8 | Demisting sensor not correctly positioned. | Refit the sensor in the correct position. | |
| 8 | CHECK ELECTRICAL CONNECTIONS | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check whether the electrical wiring connections between the Climate Control Node and the distribution actuator are loose/damaged. Disconnect/reconnect the connection to the Climate Control Node and to the actuator and to the demisting sensor. Check the continuity/insulation of the electrical connection between the Climate Control Node and the distribution actuator and the sensor. | Move on to Step 9 | 1.Electrical connections loose/damaged | 1. Restore the correct wiring. | |
| 2.Electrical connection broken or not insulated. | 2. Restore the continuity/insulation of the electrical connection. | |||
| 9 | CHECK ON CORRECT OPERATION OF DISTRIBUTION ACTUATOR | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check the operation activating the function that the actuator should carry out manually. With the vehicle moving, switch on the passenger compartment fan at the maximum speed (6 bars on the display), place the flaps in the max. def. position using the control/control unit (manually) and check the air flow in the passenger compartment by placing your hand over the vents. | End of diagnosis | Flow of air to the windscreen insufficient. | Replace the distribution actuator op. 5040D56 | |
| 10 | DISTRIBUTION ACTUATOR FLAP CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check that the actuator flap completes its travel without any impediment. | End of diagnosis | 1. Flap travel incomplete. | 1. Free the air mixture actuator flap from the impediment. | |
| 2. Flap damaged. | 2. Replace the flap. | |||
| 3. Kinematic mechanism / components damaged. | 3. Repair kinematic mechanism. |
Parts & tools for this job Staging For 2005 Alfa Romeo 159
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Alfa Romeo 159 2005 cabin filter
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.