01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Alfa Romeo 159 Factory Service Manual (2005-2011)23 · Fault diagnosis
23 · Diagnostics

Climate control air flow irregular

Make
Alfa Romeo
Model
159 Factory Service Manual
Year
2005–2011
Section
Climate control › Climate control air flow irregular
Fault diagnosisClimate control air flow irregular

CLIMATE CONTROL AIR FLOW IRREGULAR

Automatic Air Conditioning

The flow of air sent by the fan in the passenger compartment using the manual speed control is not sufficient; it does not correspond to the speed set.

0PRELIMINARY CHECKSALL OKPROBLEMS ENCOUNTEREDACTION
Connect the Examiner diagnostic equipment and check the following at the Body Computer Node: - that the Logistic Mode is deactivated (with this function activated there is a limit on the passenger compartment heater fan speed)Move on to Step 1Logistic Mode function activated.Deactivate the Logistic Mode function.
1BATTERY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Disconnect the battery and reconnect it with the Key Off and wait for 2 minutes for the Key On checking whether there is a variation in the air flow rate.End of diagnosisThere is no variation in the air flow rate.Move on to Step 2
2CHECK ON OPERATION OF FAN BY CLIMATE CONTROL SYSTEM CONTROL UNITALL OKPROBLEMS ENCOUNTEREDACTION

With the engine started, set the climate control system control unit to the AUTO position, adjust the temperature to 22°C, place the recirculation at the outside air intake and the distribution to the front position.

Adjust the fan button (+ side) gradually increasing the speed set and then decrease the speed using the button (- side), thereby checking the effect of the air flow rate variation.

End of diagnosisThere is no variation in the air flow rate.Move on to Step 3
3CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION

Connect the Examiner diagnostic equipment and check the following at the Climate Control Node:

  • that there are no errors at the passenger compartment fan;
  • that there are no errors at the distribution actuators;
  • that there are no errors linked to the fan (short circuit errors).
Move on to Step 41. Error at the passenger compartment fan.1. Move on to Step 7
2. Short circuit to earth error at the distribution actuators.2. Check that the Lin Bus cables are not caught between the metal parts (pay special attention to the gearbox bolts) and move on to Step 7.
3. Short circuit to error to +12V at the distribution actuators.3. Check that the Lin Bus cables are not caught between the metal parts (pay special attention to the gearbox bolts) and move on to Step 7.
4. Mechanical lock error / interference at the distribution actuators.4. Move on to Step 9
5. Short circuit error at the passenger compartment fan.5. Move on to Step 7
4CHECKS USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Keeping the Examiner diagnostic equipment connected, check the following through active diagnosis: - the correct operation of the air distribution actuatorsMove on to Step 5Air distribution actuator not working.Move on to Step 6.
5CHECK ON AIR DUCTS AND POLLEN FILTERALL OKPROBLEMS ENCOUNTEREDACTION
Check that the air ducts are intact and the vents are not blocked and are correctly positioned in the opening. Check that the pollen filter is not obstucted.Move on to Step 51. Air ducts or vents obstructed.1. Restore the operation of the air ducts and the vents removing any material causing an obstruction.
2. Pollen filter blocked.

2. Replace the pollen filter

Op. 5010B09 PURIFYING (POLLEN) FILTER FILTER ELEMENT - REPLACE

6ELECTRICAL CIRCUIT CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check the continuity/insulation and visually inspect for any looseness or damage at the electrical connection contacts:

  • of the air distribution actuators
  • of the climate control system control unit connector

See E6020 AIR CONDITIONING

Move on to Step 71. Electrical connections loose or damaged.1. Renew the electrical connections.
2. Electrical connection broken or not insulated.2. Restore the continuity/insulation of the electrical connection.
7CHECK ON ELECTRICAL CONNECTIONS AND FAN OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION

Check whether the electrical wiring connections are loose.

Disconnect/reconnect the connection to the engine mounting.

Disconnect the connector and connect to a feeder.

In these conditions the motor should rotate at the maximum speed indicating that the operating module is not working

Move on to Step 81.Electrical connections loose.

1.Renew the correct connections

See E6020 AIR CONDITIONING

2.The fan does not work.

2.Replace the fan

Op. 5040C30 AIR CONDITIONING FAN - R.R.

3.The operating module does not work.

3.Replace the fan operating module

Op. 5040C40

8CHECK ON CORRECT OPERATION OF DISTRIBUTION ACTUATORALL OKPROBLEMS ENCOUNTEREDACTION

Check whether the electrical wiring connections are loose.

Disconnect and visually inspect for damage at the connector contacts and reconnect the connection to the motor mounting.

If it persists, before replacing the actuator, check its operation by manually activating the function that the actuator should carry out.

With the engine running, switch on the fan at maximum speed.

Place the flaps in the various distribution positions via the control/control unit (manually).

Check the air flow in the passenger compartment with your hand at the vents.

End of diagnosis1. Electrical connections loose or damaged.

1. Renew the electrical connections

See E6020 AIR CONDITIONING

2. There is no air flow intake into the passenger compartment through the vents.2. Move on to Step 9.
9CHECK FOR IMPEDIMENTS TO THE ROTATION OF THE DISTIRUBTION ACTUATORALL OKPROBLEMS ENCOUNTEREDACTION
Remove the actuator and check using the control unit control that the actuator turns checking for mechanical impediments to its rotation.End of diagnosis1.The actuator does not turn.

1.Replace the timing actuator

Op. 5040D63 AIR DISTRIBUTION FLAP CONTROL ACTUATORS- R.R. WITH AIR CONDITIONING CASING REMOVED

2.Kinematic components or flaps broken/stuck2.Replace the components that is faulty.

Manual Air Conditioning

The flow of air sent by the fan in the passenger compartment using the manual speed control is not sufficient; it does not correspond to the speed set.

0PRELIMINARY CHECKSALL OKPROBLEMS ENCOUNTEREDACTION
Disconnect the battery and reconnect it with the Key Off and wait for 2 minutes for the Key On checking whether there is a variation in the air flow rate.End of diagnosisThere is no variation in the air flow rate.Move on to Step 1
1AIR DUCTS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the air ducts are intact and the vents are not blocked and are correctly positioned in the opening.Move on to Step 21.Air ducts or vents obstructed1.Restore the operation of the air ducts and the vents removing any material causing an obstruction.
2.The flow of air does not correspond to the distribution selected.2.Move on to Step 8.
2CHECK ON CORRECT OPERATION OF MAXIMUM SPEED RELAYALL OKPROBLEMS ENCOUNTEREDACTION

Check for loose electrical wiring connections, disconnect visually inspecting for any damage to the connector contacts.

Reconnect the connection to the resistor.

Check that the fan is working at the maximum speed: if it only works at the maximum speed, the relay is broken.

Check whether the resistor is broken by checking the electrical continuity in accordance with the

See Test 5040CF Sequential procedure for checking air conditioner fan resistor operation

Move on to Step 31.Electrical connections loose or damaged.

1. Renew the electrical connections

See E6020 AIR CONDITIONING

2.Relay broken.

2.Replace the ceramic resistor

Op. 5040C48

3.Resistance values faulty

2.Replace the ceramic resistor

Op. 5040C48

3CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the Examiner diagnostic equipment and check the following at the Climate Control Node: - that there are no errors at the distribution actuatorMove on to Step 41. Short circuit to earth error

1. Renew the correct electrical connections

See E6020 AIR CONDITIONING

2. Short circuit to +12V error

2. Renew the correct electrical connections

See E6020 AIR CONDITIONING

3. Mechanical interference / stuck error3. Move on to Step 10.
4CHECKS USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Keeping the Examiner diagnostic equipment connected, check the following through active diagnosis: - the correct operation of the air distribution actuatorMove on to Step 6Air distribution actuator not working.Move on to Step 5.
5ELECTRICAL CIRCUIT CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check the continuity/insulation and visually inspect for any looseness or damage at the electrical connection contacts:

  • of the air distribution actuators
  • of the climate control system control unit connector

See E6020 AIR CONDITIONING

Move on to Step 61. Electrical connections loose or damaged.1. Renew the electrical connections.
2. Electrical connection broken or not insulated.2. Restore the continuity/insulation of the electrical connection.
6CHECK ON CORRECT OPERATION OF SPEED SELECTOR AT THE CLIMATE CONTROL SYSTEM CONTROL UNITALL OKPROBLEMS ENCOUNTEREDACTION

Check for loose electrical wiring connections, disconnect visually inspecting for any damage to the connector contacts.

Reconnect the connection to the selector at the climate control system control unit.

Check whether the selector on the control unit is interrupted by checking the electrical continuity in accordance with the

See Test 5040DF Sequential procedure for checking air conditioner fan operation

Move on to Step 71.Electrical connections loose or damaged.

1. Renew the electrical connections

See E6020 AIR CONDITIONING

2.Fan not working.

2.Replace the speed selector knob

Op. 5040D23

3.Power supply to the relays not correct.

3.Replace the climate control system control unit

Op. 5040D17

7CHECK ON CORRECT OPERATION OF FANALL OKPROBLEMS ENCOUNTEREDACTION

Check whether the electrical wiring connections are loose.

See E6020 AIR CONDITIONING

Disconnect, visually inspecting for any damage to the connector contacts.

Reconnect the connection to the engine mounting.

Check that it rotates at all speeds by activating it using the switch.

If it does not rotate at maximum speed, check the fan maximum speed relay

See J041

Move on to Step 81.Electrical connections loose or damaged

1. Renew the electrical connections

See E6020 AIR CONDITIONING

2. Electric fan

2.Replace the fan

Op. 5040C30 AIR CONDITIONING FAN - R.R.

8CHECK ON CORRECT OPERATION OF FAN MAXIMUM SPEED OPERATING RELAYSALL OKPROBLEMS ENCOUNTEREDACTION

Check whether the electrical wiring connections are loose.

Disconnect, visually inspecting for any damage to the connector contacts.

Reconnect the connection to the relay.

Check that the relay is working properly by providing it with a direct 12 V supply.

Move on to Step 9.1.Electrical connections loose or damaged

1. Renew the electrical connections

See E6020 AIR CONDITIONING

2.Maximum speed operating relay not working.

2.Replace the maximum speed operating relay

Op. 5040C48

9CHECK ON CORRECT OPERATION OF DISTRIBUTION ACTUATORALL OKPROBLEMS ENCOUNTEREDACTION

Check whether the electrical wiring connections are loose.

Disconnect and visually inspect for damage at the connector contacts and reconnect the connection to the motor mounting.

If it persists, before replacing the actuator, check its operation by manually activating the function that the actuator should carry out.

With the engine running, switch on the fan at maximum speed.

Place the flaps in the various distribution positions via the control/control unit.

Check the air flow in the passenger compartment with your hand at the vents.

End of diagnosis1. Electrical connections loose or damaged.

1. Renew the electrical connections

See E6020 AIR CONDITIONING

2. There is no air flow intake into the passenger compartment through the vents.2. Move on to Step 10
10CHECK FOR IMPEDIMENTS TO THE ROTATION OF THE DISTIRUBTION ACTUATORALL OKPROBLEMS ENCOUNTEREDACTION
Remove the actuator and check using the control unit control that the actuator turns checking for mechanical impediments to its rotation.End of diagnosis1.The actuator does not turn.

1.Replace the timing actuator

Op. 5040D63

2.Kinematic components or flaps broken/stuck2.Replace the components that is faulty.