Workshop Manuals Factory service & repair Alfa Romeo
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Alfa Romeo 159 Factory Service Manual (2005-2011)17 · Electrical equipment
17 · Electrical

Battery charge check

Make
Alfa Romeo
Model
159 Factory Service Manual
Year
2005–2011
Section
Current generation › Battery charge check
Electrical equipmentBattery charge check

BATTERY CHARGE CHECK

Check 5530BC

1.9 JTS, 2.2 JTS, 3.2 JTS, 1.9 JTD 8V, 1.9 JTD 16V, 2.4 JTD 20V

CHECK TO BE PERFORMEDRESOLUTION IF THE CHECK IS NOT OK
1

Remove the battery cover.

Check visually to ensure the battery terminals are not oxidised

Clean the layer of oxidation from the terminals
2The water gauge (magic eye) should not be white indicating that the electrolyte level is too low.

Replace the battery

Op. 5530B10 BATTERY - R+R

3The plugs or caps should not be damaged or incorrectly positioned

Replace the battery

Op. 5530B10 BATTERY - R+R

4There should be no damage to the main body of the battery, the cover or the terminals

Replace the battery

Op. 5530B10 BATTERY - R+R

5There should be no signs of electrolyte escaping from the battery (wet areas or large salt deposits)Clean the area involved and top up to the correct level
6

Check that the vehicle has not been used for at least 30 minutes.

Disconnect the negative terminal and check the battery charge using the MICRO 360 equipment, tool code 1806367006, making sure that it is connected directly to the battery terminals.

The equipment will give one of the following signals "CHARGE RETEST" or "BATT. OK+RECHARGE" or the display will remain off.

Move on to Step 11

Move on to Step 7
7The equipment will give one of the following signals "REPLACE BATT." or "CELL SHORT". Go on to Step 10Move on to Step 8
8

Check the electrical connections for the supply circuit are correct with particular reference to the power supplies and earths

See E1010 POWER SUPPLY

Restore the correct connections

See E1010 POWER SUPPLY

9

Reconnect or refit the battery on the vehicle and try and start the engine several times (at least 6 or 7) with about 4-5 seconds between each attempt.

Make sure that the engine starts successfully each time.

The test can be considered over

Continue with Step 8

See Test 5530BB BATTERY VOLTAGE CHECK

10

Replace the battery

Op. 5530B10 BATTERY - R+R

The test can be considered over

11Rechare the battery using tool 1806151001
12

Check the battery charge using the MICRO 360 equipment, tool code 1806367006, making sure that it is connected directly to the battery terminals.

The equipment will give one of the following signals "RETEST CHARGE." or "REPLACE BATT." or "CELL SHORT" or the display will remain off

Move on to Step 9

Move on to Step 10

Parts & tools for this job Staging For 2005 Alfa Romeo 159

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.