B01 Ignition switch not working
When the ignition is turned ON nothing happens. The starter motor does not turn, the instruments do not light up
| Step | Test procedure | Result | Action |
|---|---|---|---|
| 1 | BATTERY EFFICIENCY CHECK Check the efficiency of the battery using the appropriate diagnostic equipment | OK | |
| Battery not working properly |
End of diagnosis | ||
| 2 | CHECK FASTENINGS Check, in order:
| OK | |
| Cable fastenings at battery slack |
End of diagnosis | ||
| Earth lead frayed |
End of diagnosis | ||
| Connections with slack fastenings |
End of diagnosis | ||
| Maxifuse burnt |
End of diagnosis | ||
| 3 | SUPPLY CHECK Check switch supply | OK | |
| No supply reaches the switch |
End of diagnosis | ||
| 4 | SWITCH CHECK Check condition and correct operation of the switch | OK | |
| Switch contacts not working properly |
End of diagnosis | ||
| 5 | CORRECT OPERATION CHECK Check that the fault is no longer present | OK | Incorrect selection of diagnostic procedure |
| Fault persists | Incorrect selection of diagnostic procedure |