01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Lancia Ypsilon Factory Service Manual (2003-2011)22 · Fault diagnosis
22 · Diagnostics

Rich fuel system

Make
Lancia
Model
Ypsilon Factory Service Manual
Year
2003–2011
Section
Examiner › Rich fuel system
Fault diagnosisRich fuel system

RICH FUEL SYSTEM

1.2 8v, 1.2 16v, 1.4 16v

Results of the tests
1CANISTER VALVE CHECKAll OKProblems metOperation
Check that the canister valve is not stuck openContinue to Step 2Canister valve stuck open

Repair or, if necessary, replace the canister Op. 1080E20

Continue to Step 5

2INTAKE AND EXHAUST SYSTEM LEAKAGE CHECKAll OKProblems metOperation

Check the blow-by circuit, visually checking that there are no leaks from the engine sump to the intake circuit.

Also check, visually and by listening, that there are no leaks from the intake and exhaust systems

Continue to Step 3There are leaks

Eliminate leaks from the system. Replace faulty parts if necessary

Continue to Step 5

3PETROL PRESSURE CHECKAll OKProblems metOperation

Turn the key to MAR and check that fuel pump activates.

While the pump is active, check fuel pressure is not too high.

Turn the ignition off and check that the pressure does not fall by more than 1 bar over a period of 15 minutes.

Continue to Step 4High pressure: fuel pressure regulator setting not correct

Replace the fuel pupm Op. 1040A70

Continue to Step 5

The pressure falls by more than 1 bar in the established time: faulty injectors

Renew the correct seal for the injectors, if necessary replace them Op. 1056B70

Continue to Step 5

The pressure falls by more than 1 bar in the established time: leaks from the fuel pressure regulator

Replace the fuel pupm Op. 1040A70

Continue to Step 5

The pressure falls by more than 1 bar in the established time: leaks from the non-return valve on the fuel pump

Replace the fuel pupm Op. 1040A70

Continue to Step 5

4UPSTREAM LAMBDA SENSOR CHECKAll OKProblems metOperation
Continue as instructed See table Z56 UPSTREAM LAMBDA SENSOR SIGNAL ERROR, starting from Step 3End of diagnosis
5ERROR CANCELLING AND CHECKINGAll OKProblems metOperation

Use a tester to cancel the errors in the control unit.

Road test the vehicle and check that the error does not occur again

Continue to Step 6The fault persistsContinue to Step 1
6CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosis