Valve tappets - check clearance
- Make
- Lancia
- Model
- Ypsilon Factory Service Manual
- Year
- 2003–2011
- Section
- Timing system › Valve tappets - check clearance
Valve tappets - check clearance
Removing
Proceed with removal - 1048A10 air cleaner filtering element - replace.
Proceed with removal - 1016A20 single cam cover - r + r and replace gasket.
Act on the drive pulley bolt using a suitable spanner so that the valves are in the closed position.
With the engine cold, check, using a feeler gauge, that with the valves in a closed position the clearance is within the recommended values.
| Measurement | Value | ||
|---|---|---|---|
| Valve clearance (mm) | Exhaust | 0.40 ÷ 0.50 | |
| Inlet | 0.30 ÷ 0.40 | ||
Refitting
Proceed with refitting - 1016A20 single cam cover - r + r and replace gasket.
Proceed with refitting - 1048A10 air cleaner filtering element - replace.
Parts & tools for this job Staging For 2003 Lancia Ypsilon
- PARTEngine gasket setSearch: Lancia Ypsilon 2003 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set