01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Fiat Panda Factory Service Manual (2003-2012)23 · Fault diagnosis
23 · Diagnostics

Milometer not working

Make
Fiat
Model
Panda Factory Service Manual
Year
2003–2012
Section
Instrument panel › Milometer not working
Fault diagnosisMilometer not working

MILOMETER NOT WORKING

The milometer either does not work or does not work properly whilst driving. the speedometer works properly.

If the speedometer is also not working correctly, see See table K03 SPEEDOMETER NOT WORKING

the milometer signal is supplied by the Body Computer Node using the signals coming from the Brake Node.

Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation
Check that no failure message is displayed with the engine started upContinue to Step 2There are faults detectedContinue to Step 1
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Connect the diagnostic equipment (Examiner) to the Body Computer.

Check the following on the CAN information network:

  • for inactive control units;
  • control unit errors;
  • absence of control unit with error in CAN line
Continue to Step 2Presence of faults in the CAN networkContinue following the instructions for the diagnostic equipment
Presence of errors at instrument panel nodeContinue to Step 2
2CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the diagnostic equipment (Examiner) to the diagnostic socket or keep it connected and check that there are no faults at the instrument panel nodeContinue to Step 3Presence of errors or failed dialogue with the diagnostic equipmentContinue following the instructions for the diagnostic equipment
3CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Keep the diagnostic equipment (Examiner) connected to the diagnostic socket and check the operation of the display by means of active diagnosisContinue to Step 4Milometer not workingReplace instrument panel Op. 5560B11
4Continue as instructed by the testerAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosis

Parts & tools for this job Staging For 2003 Fiat Panda