Workshop Manuals Factory service & repair Fiat
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Fiat Panda Factory Service Manual (2003-2012)23 · Fault diagnosis
23 · Diagnostics

Display does not show outside temperature

Make
Fiat
Model
Panda Factory Service Manual
Year
2003–2012
Section
Instrument panel › Display does not show outside temperature
Fault diagnosisDisplay does not show outside temperature

DISPLAY DOES NOT SHOW OUTSIDE TEMPERATURE

With the ignition ON, the reconfigurable matrix does not display the outside temperature;

the temperature information is supplied directly to the instrument panel node by the sensor on the driver's door mirror

Results of the tests
0PRELIMINARY CHECKAll OKProblems metOperation

Check that with the ignition switched ON:

  • that there are no dashes displayed in place of the temperature
  • that there are no failure messages displayed
Continue to Step 2Display shows information describedRestore the standard screen on the matrix that can be reconfigured
There are dashes in place of the temperature.Continue to Step 1
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Connect the diagnostic equipment (Examiner or other instruments) and check the CAN network information:

  • for inactive control units;
  • control unit errors;
  • absence of control unit with error in CAN line
Continue to Step 2Presence of faults in the CAN networkContinue following the instructions for the diagnostic equipment
Presence of errors at instrument panel nodeContinue to Step 2
2CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Keep the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check that there are no faults at the instrument panel nodeContinue to Step 3Presence of errors or failed dialogue with the diagnostic equipmentContinue following the instructions for the diagnostic equipment
3CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Keeping the diagnostic equipment (Examiner or other instruments) connected to the diagnostic socket, check the operation of the reconfigurable matrix through active diagnosis.Continue to Step 4Display that can be reconfigured not workingReplace instrument panel Op. 5560B11
4CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosis

Parts & tools for this job Staging For 2003 Fiat Panda

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.