Workshop Manuals Factory service & repair Fiat
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Fiat Panda Factory Service Manual (2003-2012)23 · Fault diagnosis
23 · Diagnostics

Clock not working

Make
Fiat
Model
Panda Factory Service Manual
Year
2003–2012
Section
Instrument panel › Clock not working
Fault diagnosisClock not working

CLOCK NOT WORKING

With the ignition ON, the display does not display the time correctly or at all.

Results of the tests
1INSTRUMENT PANEL FUNCTIONS CHECKAll OKProblems metOperation

Check:

  • That the display shows the correct time
  • That it is possible to adjust the time
  • That the clock moves forward
  • That the instrument panel light dimmer has not been selected.
  • That the mode button has not been pressed.
  • That there are no failure messages displayed.
Continue to Step 2The time displayed is not correctAdjust the time
The time cannot be adjustedContinue to Step 2
The clock is stuckReplace instrument panel Op. 5560B11
The time is not displayed because there are priority messages or adjustments in progress.Remove the cause of the priority messages
The display/time cannot be seen properlyContinue to Step 2
2CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Connect the Examiner equipment to the diagnostic socket and check that there are no faultsContinue to Step 3There are errorsContinue according to the instructions for the diagnostic equipment
3CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Keeping the Examiner connected to the diagnostic socket, check the operation of the display in active diagnosisContinue to Step 4Defective displayReplace instrument panel Op. 5560B11
4CHECK ON ELECTRICAL CIRCUITAll OKProblems metOperation
Check instrument panel power supply and earth See E4010 INSTRUMENT PANELContinue to Step 5Connections defective, earth or supply defectiveRestore the correct connections, if necessary, replace the wiring See E4010 INSTRUMENT PANEL
5CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosis

Parts & tools for this job Staging For 2003 Fiat Panda

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.