Check operation of LPG pump
- Make
- Fiat
- Model
- Multipla Factory Service Manual
- Year
- 1998–2010
- Section
- Lgp tank and pipes › Check operation of LPG pump
Check operation of LPG pump
The operating test consists of a test on the total absorption by the following loads:
LPG pump.
Solenoid positioned on LPG cylinder.
Solenoid positioned on pressure regulator.
Proceed as follows:
Measure the battery voltage with all the loads switched off, and make sure that the no-load voltage is not less than 12.8 V; if it is, recharge the battery.
Turn the ignition key to the OFF position.
Fit an ammeter lead to the battery's negative cable.
Disconnect the relay.
| Name | Connector | |
|---|---|---|
| Methane/LPG relay feed | J26 |
Bridge terminals 30 and 87 with a piece of cable containing a 7.5 A fuse.
Check that the total absorption of the supplied loads is about 5 A.