Workshop Manuals Factory service & repair Fiat
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Multipla Factory Service Manual (1998-2010)08 · Engine
08 · Engine

Check operation of LPG pump

Make
Fiat
Model
Multipla Factory Service Manual
Year
1998–2010
Section
Lgp tank and pipes › Check operation of LPG pump
EngineCheck operation of LPG pump

Check operation of LPG pump

Check 1043AA

1.6 16v · GPOWER

The operating test consists of a test on the total absorption by the following loads:

LPG pump.

Solenoid positioned on LPG cylinder.

Solenoid positioned on pressure regulator.

Proceed as follows:

Measure the battery voltage with all the loads switched off, and make sure that the no-load voltage is not less than 12.8 V; if it is, recharge the battery.

Turn the ignition key to the OFF position.

Fit an ammeter lead to the battery's negative cable.

Disconnect the relay.

NameConnector
Methane/LPG relay feedJ26

Bridge terminals 30 and 87 with a piece of cable containing a 7.5 A fuse.

Check that the total absorption of the supplied loads is about 5 A.