METHANE TEMPERATURE AND PRESSURE SENSOR CHECK
PRESSURE SENSOR CHECK
- The electrical check is carried out by placing a bridge between the sensor and the connector and measuring the output signal using a voltmeter.
- With the diagnostic equipment in the "Voltmeter" function, check, with the ignition ON, that the supply voltage between pin 4 of the pressure sensor and earth is around 5 V.
- Check that the voltage between pin 2 and earth is 3.5V at a pressure of about 10 bar.
- Check that the voltage between pin 2 and earth is 0.5V at a pressure below 1 bar.
TEMPERATURE SENSOR CHECK
- Disconnect the methane temperature/pressure sensor connector.
- Connect to the diagnostic equipment in the Ohmmeter function.
- Connect the diagnostic equipment probes between pins 1 and 3 of the sensor and measure the resistance proportional to the temperature of the gas as set out in the enclosed table.
| NOMINAL RESISTANCE (Ohm) | TEMPERATURE (°C) |
|---|---|
| 167835 | -40 |
| 48487 | -20 |
| 16325 | 0 |
| 6246 | 20 |
| 2662 | 40 |
| 1243 | 60 |
| 628 | 80 |
| 339 | 100 |
| 194 | 120 |
| 117 | 140 |