Workshop Manuals Factory service & repair Alfa Romeo
01 General data and specifications02 Maintenance03 Diagnosis – checks04 Engine (1.6 and 2.0 Twin Spark)05 Clutch06 Gearbox (manual and Selespeed)07 Front axle08 Brakes, ABS and traction control09 Steering10 Suspension and wheels11 Heating, air conditioning and washers12 Electrical equipment13 Body14 Body panels and reinforcement15 Wiring diagrams16 Connectors and pin-outs17 Wiring harnesses18 Fault diagnosis19 Special tools
Alfa Romeo 147 Factory Service Manual (2000-2002)18 · Fault diagnosis
18 · Diagnostics

B10 Engine fails to start in any condition

Make
Alfa Romeo
Model
147 Factory Service Manual
Year
2000–2002
Section
Starting › B10 Engine fails to start in any condition
Fault diagnosisB10 Engine fails to start in any condition

B10 Engine fails to start in any condition

StepTest procedureResultAction
0PRELIMINARY CHECKS

Turn the key to the ON position and check that the I.E and CODE lights come on for the start-up test

NOTE: The I.E light should come on for about 4 seconds and then switch off, while the CODE light should come on for about 1 second and the switch off.

Check

  • that the inertia switch has not cut in
  • the condition of the spark plugs and leads
  • that there are no obstructions in the catalytic converter;
  • that there is no water in the fuel
OK

Move onto step 1

that the I.E light remains on

End of diagnosis

Both lights remain on

End of diagnosis

The code light remains on

End of diagnosis

The I.E light does not cary out the start-up test

End of diagnosis

The CODE light does not carry out the start-up test

End of diagnosis

The warning lights do not do the initial test

End of diagnosis

Operation of inertia switch
  • Restore correct operation

End of diagnosis

Spark plugs dirty or worn

End of diagnosis

Spark plug leads damaged
  • Replace the leads

End of diagnosis

Catalytic converter/s blocked
  • Replace catalytic converter/s

End of diagnosis

Water in the carburettor
  • Clean the tank

End of diagnosis

1CHECK WITH DIAGNOSTIC EQUIPMENT

Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socket

Verify:

  • that there are no errors in the control unit
  • the plausibiilty of the parameters
OK

Move onto step 2

Error detected in the control unit
  • Continue following the instructions for the diagnostic equipment

End of diagnosis

Implausible parameters
  • Continue following the instructions for the diagnostic equipment

End of diagnosis

2ACTIVE TESTING OF FUEL PUMP

Carry out active testing of fuel pump and check if it is working properly

OK

Move onto step 4

Pump not working

Move onto step 3

3PETROL PUMP ELECTRICAL CIRCUIT CHECK

Check the petrol pump supply and earth Wiring diagram E5030 PETROL ENGINES ELECTRONIC CONTROL

OK

Move onto step 4

Connections not correct

End of diagnosis

Pump faulty

End of diagnosis

4CHECKING DELIVERY PRESSURE

Check that the fuel pressure is correct Op. 0510C10

OK

Move onto step 5

Pressure not correct
  • Eliminate any obstructions in the pipes. If necessary, replace the pump assembly Op. 1040A70

End of diagnosis

5CHECKING CORRECT OPERATION

Check that the fault is no longer present

OK

Incorrect selection of diagnostic procedure

Fault persists: control unit defective

Incorrect selection of diagnostic procedure

Parts & tools for this job Staging For 2000 Alfa Romeo 147