Battery charging warning light not working
- Make
- Lancia
- Model
- Ypsilon Factory Service Manual
- Year
- 2003–2011
- Section
- Instrument panel › Battery charging warning light not working
Fault diagnosisBattery charging warning light not working
BATTERY CHARGING WARNING LIGHT NOT WORKING
When the ignition is turned on, the generator warning light does not come on.
| Results of the tests | ||||
| 1 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
|---|---|---|---|---|
Connect the Examiner to the diagnostic socket Carry out the active diagnosis of the warning lights | Continue to Step 2 | The warning light does not come on | Replace instrument panel Op. 5560B11 | |
| 2 | CHECKING ELECTRICAL EQUIPMENT | All OK | Problems met | Operation |
| Check body computer power supply is correct, particularly the D+ and +15 signal See E5010 STARTING AND RECHARING | Continue to Step 3 | Body Computer supply incorrect | Restore correct power supply | |
| 3 | BATTERY CHECK | All OK | Problems met | Operation |
| Check the operation of the battery | Continue to Step 4 | Battery not working | Replace the battery Op. 5530B10 | |
| 4 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | |||