Climate control not working / (no air delivery)
- Make
- Lancia
- Model
- Ypsilon Factory Service Manual
- Year
- 2003–2011
- Section
- Climate control › Climate control not working / (no air delivery)
‹ Prev Climate control not working / under no circumstancesNext › Climate control air flow irregular
Fault diagnosisClimate control not working / (no air delivery)
CLIMATE CONTROL NOT WORKING / (NO AIR DELIVERY)
When the activation switch is pressed, the air conditioner system works correctly but no air comes out of any of the diffusers.
The climate control unit fan power supply is protected by specific fuses and controlled by a relay, housed in the engine bay control unit.
| Results of the tests | ||||
| 0 | PRELIMINARY CHECK | All OK | Problems met | Operation |
|---|---|---|---|---|
| Check the condition of the fan fan power supply fuses and relay. | Continue to Step 1 | Fuses blown | Change blown fuses | |
| Relay damaged | Change damaged relay | |||
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Connect an Examiner and check fan motor operation via active diagnosis. | Continue to Step 5 | Fan motor malfunction | Continue to Step 2 | |
| 2 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation |
| Check fan motor power supply See E6020 AIR CONDITIONING | Continue to Step 3 | No power supply | Restore continuity/insulation of the electrical connection between fan motor and fan control unit See E6020 AIR CONDITIONING | |
| 3 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation |
| Check continuity/insulation of the electrical connection between fan motor and climate control system node See E6020 AIR CONDITIONING | Continue to Step 4 | Electrical conection broken or not insulated. | Restore electrical connection continuity/insulation. See E6020 AIR CONDITIONING | |
| 4 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present. | End of diagnosis | Fault persists | Change fan motor | |
| 5 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Change the climate control system node | |
‹ Prev Climate control not working / under no circumstancesNext › Climate control air flow irregular
Parts & tools for this job Staging For 2003 Lancia Ypsilon
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Lancia Ypsilon 2003 cabin filter
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.