01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Transmission (4x4)12 Axles and driveshafts13 Brakes14 Steering15 Suspension and wheels16 Heating, air conditioning and auxiliary units17 Electrical equipment18 Body fittings19 Body panels and frame20 Wiring diagrams and electrical functions21 Wiring harnesses22 Connectors and pin-outs23 Fault diagnosis24 Special tools
Fiat Panda Factory Service Manual (2003-2012)23 · Fault diagnosis
23 · Diagnostics

Battery charge status check

Make
Fiat
Model
Panda Factory Service Manual
Year
2003–2012
Section
Starting › Battery charge status check
Fault diagnosisBattery charge status check

BATTERY CHARGE STATUS CHECK

1VISUAL INSPECTION OF BATTERYAll OKProblems encounteredOperation

Remove the battery cover and visually inspect the state of the battery and the terminals.

More specifically:

  • The terminals should not be oxidzed
  • The water gauge (magic eye) should not be white indicating that the electrolyte level is too low
  • The plugs or caps should not be damaged or incorrectly positioned
  • There should be no damage to the main body of the battery, the cover or the terminals
  • There should be no signs of electrolyte escaping from the battery (wet areas or large salt deposits)
Move on to Step 2
  • Terminals oxidized
  • Electrolyte level too low (the magic eye is white)
  • Problems with the plugs and/or caps
  • Damage to the body, cover and/or terminals
  • Electrolyte level too high
2CHECK USING MIDTRONIC EQUIPMENTAll OKProblems encounteredOperation

Check that the vehicle has not been used for at least 30 minutes.

Disconnect the negative terminal and check the battery charge using the MICRO 360 equipment, tool code 1806367006, making sure that it is connected directly to the battery poles.

  • The equipment will give one of the following signals "CHARGE RETEST" or "BATT. OK+RECHARGE" or the display will remain off
  • The equipment will give one of the following signals "REPLACE BATT." or "CELL SHORT"
  • The equipment will give the signal "BATT. EFFICIENT"
  • Move on to Step 5
  • Move on to Step 6
  • Move on to Step 3
3ELECTRICAL SYSTEM CHECKAll OKProblems encounteredOperation

Check the electrical connections for the supply circuit with particular reference to the power supplies and earths

See E1010 SUPPLY

Move on to Step 4Connections faulty

Restore the correct connections

See E1010 SUPPLY

4ATTEMPTS AT STARTINGAll OKProblems encounteredOperation

Reconnect or refit the battery on the vehicle and try and start the engine several times (at least 6 or 7) with about 4-5 seconds between each attempt.

Make sure that the engine starts successfully each time

End of diagnosisThe vehicle does not start or starts with difficultyMove on to Step 8
5BATTERY RECHARGINGAll OKProblems encounteredOperation

Recharge the battery

Op. 5530B14 BATTERY - RECHARGE

using the tool 1806151001.

Move on to Step 7
6BATTERY REPLACEMENTAll OKProblems encounteredOperation

Replace the battery

Op. 5530B10 BATTERY - R+R

End of diagnosis
7CHECK USING MIDTRONIC EQUIPMENTAll OKProblems encounteredOperation
Check the battery charge using the MICRO 360 equipment, tool code 1806367006, making sure that it is connected directly to the battery poles.
  • The equipment will give one of the following signals "RETEST CHARGE." or "REPLACE BATT." or "CELL SHORT" or the display will remain off
  • The equipment will give the signal "BATT. EFFICIENT"
  • Move on to Step 6
  • Move on to Step 4
8CONTACT THE SERVICE DEPARTMENTAll OKProblems encounteredOperation
Contact Te.Se.O. for more precise instructions on how to proceedEnd of diagnosis