Workshop Manuals Factory service & repair Alfa Romeo
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Alfa Romeo GT Factory Service Manual (2003-2010)22 · Fault diagnosis
22 · Diagnostics

Boot opening/closing not working

Make
Alfa Romeo
Model
GT Factory Service Manual
Year
2003–2010
Section
Doors › Boot opening/closing not working
Fault diagnosisBoot opening/closing not working

BOOT OPENING/CLOSING NOT WORKING

When the boot is opened/closed using the key or opened using the button in the control panel, the boot does not open and does not close

Results of the tests
1FUSE AND RELAY CHECKAll OKProblems metOperation

Check the condition of the fuses and relays See

See E3045 BOOT AND FUEL FLAP OPENING

Continue to Step 2Components faultyReplace the component involved (if a fuse is involved, search for the cause of the problem)
2CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Check the opening/closing of the boot through active diagnosisContinue to Step 6The boot does not open/closeContinue to Step 3
3ELECTRICAL CIRCUIT CHECKAll OKProblems metOperation

Check the electrical connection between the body computer node, driver''s door node and the boot lock. See

See E3045 BOOT AND FUEL FLAP OPENING

Continue to Step 4Electrical connector in boot lock not correctly connectedConnect the electrical connector to the boot lock correctly
Connections broken or not insulated

Restore continuity/insulation of the electrical connection See

See E3045 BOOT AND FUEL FLAP OPENING

4CHECKING ELECTRICAL SIGNALAll OKProblems metOperation
Disconnect the boot lid lock electrical connector and check for a opening command signal.Continue to Step 5Opening command signal absent.Continue to Step 7
5Continue as instructed by the testerAll OKProblems metOperation
Check that the fault is no longer present.End of diagnosisThe fault persists

Replace the boot lock motor Op.

Op. 7015B70 TAIL-GATE LOCK MOTOR - R R AND CHECK LOCK SUPPLY LINE

6CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Press the button in the dashboard and check, in the parameters ambient, at the Driver''s Door Node, that the boot lid opening button status changesContinue to Step 9There is no change in the statusContinue to Step 7
7ELECTRICAL CIRCUIT CHECKAll OKProblems metOperation

Check the electrical connection between the switch in the dashboard and the Driver''s Door Node See

See E3045 BOOT AND FUEL FLAP OPENING

. Also check that the switch in the dashboard is working properly.

Continue to Step 8Connections broken or not insulated

Restore continuity/insulation of the electrical connection See

See E3045 BOOT AND FUEL FLAP OPENING

Switch faultyReplace the switch in the dashboard Op. 7015B80
8REPLACING DRIVER''S DOOR NODEAll OKProblems metOperation

Replace the Driver''s Door Node Op. 5505A42

and check that the fault is no longer present

End of diagnosisThe fault persists

Restore the Driver''s Door Node and replace the Body Computer Node Op.

Op. 5505A32 BODY COMPUTER - R R

9CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer present.End of diagnosisThe fault persists

Replace the body computer node Op.

Op. 5505A32 BODY COMPUTER - R R

Parts & tools for this job Staging For 2003 Alfa Romeo GT

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.