01 General data and specifications02 Engine (Twin Spark, JTD and V6)03 Clutch04 Gearbox (manual, Selespeed and Q-System)05 Front axle06 Brakes, ABS and traction control07 Steering08 Suspension and wheels09 Heating, air conditioning and washers10 Electrical equipment11 Body12 Body panels and reinforcement13 Wiring diagrams14 Connectors and pin-outs15 Wiring harnesses16 Fault diagnosis17 Special tools
Alfa Romeo 156 Factory Service Manual (1997-2002)10 · Electrical equipment
10 · Electrical

Battery - recharge

Make
Alfa Romeo
Model
156 Factory Service Manual
Year
1997–2002
Section
Current generation lighting › Battery - recharge
Electrical equipmentBattery - recharge

Battery - recharge

Operation 5530B14 · Battery and leads

NOTE: Do not on any account carry out fast recharging. To recharge the battery correctly, use a battery charger recommended by the Service Outlets (e.g. ISEAT CB1): this is a 'constant voltage' battery charger with microprocessor, which recognizes the battery conditions and automatically determines the best recharging cycle; in this way a battery charge of close to 100% can be achieved.

NOTE: Always disconnect the battery negative terminal before recharging; while recharging, do not touch the battery terminals using your hands and do not bring naked flames close to the battery; operate the battery charger only after connecting the leads to the battery.

NOTE: If the measurement of the battery voltage without load is less than 12.10 V, recharging is not recommended and the battery should be replaced (5530B10 Battery - r+r ).